Advances in capillary electrochromatography: Rapid and high-efficiency separations of PAHs

被引:78
作者
Dadoo, R
Zare, RN
Yan, C
Anex, DS [1 ]
机构
[1] Stanford Univ, Dept Chem, Stanford, CA 94305 USA
[2] Unimicro Technol Inc, Pleasanton, CA 94566 USA
[3] Sandia Natl Labs, Livermore, CA 94551 USA
关键词
D O I
10.1021/ac9803028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary columns packed electrokinetically with 1.5-mu m nonporous octadecylsilica particles are used to achieve rapid separations with high efficiencies. A mixture containing five polycyclic aromatic hydrocarbons (PAHs) as test compounds is separated in less than 5 s with 28 kV applied to a column with a packed length of 6.5cm (10 cm total length). A sample containing 16 PAHs (classified as priority pollutants by the U.S. Environmental Protection Agency) is isocratically separated in under 10 min by using longer columns (15-30 cm). Separation efficiencies greater than 700 000 theoretical plates/m are obtained when detection (via W-excited laser-induced fluorescence) is performed on the packed portion of the capillary. The outlet frit is observed to play an important role in determining column efficiency. The optimum now rate for best separation efficiency occurs at similar to 2 mm/s. The run-to-run reproducibility of the peak retention times on a single column is better than 1% (relative standard deviation).
引用
收藏
页码:4787 / 4792
页数:6
相关论文
共 42 条
  • [1] EVALUATION OF THE PARAMETERS DETERMINING THE PERFORMANCE OF ELECTROCHROMATOGRAPHY IN PACKED CAPILLARY COLUMNS
    BEHNKE, B
    GROM, E
    BAYER, E
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) : 207 - 213
  • [2] CAPILLARY ELECTROCHROMATOGRAPHY - SOME IMPORTANT CONSIDERATIONS IN THE PREPARATION OF PACKED CAPILLARIES AND THE CHOICE OF MOBILE-PHASE BUFFERS
    BOUGHTFLOWER, RJ
    UNDERWOOD, T
    PATERSON, CJ
    [J]. CHROMATOGRAPHIA, 1995, 40 (5-6) : 329 - 335
  • [3] THE REPEATABILITY OF THE QUANTITATIVE-ANALYSIS IN ELECTROCHROMATOGRAPHY
    COUFAL, P
    CLAESSENS, HA
    CRAMERS, CA
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (17): : 3623 - 3652
  • [4] Automated capillary electrochromatography: Reliability and reproducibility studies
    Dulay, MT
    Yan, C
    Rakestraw, DJ
    Zare, RN
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 725 (02) : 361 - 366
  • [5] PRESSURIZED FLOW ELECTROCHROMATOGRAPHY WITH REVERSED-PHASE CAPILLARY COLUMNS
    EIMER, T
    UNGER, KK
    TSUDA, T
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (7-8): : 649 - 653
  • [6] Direct on-line injection in capillary electrophoresis
    Evans, CE
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (15) : 2952 - 2954
  • [7] EVERAERTS FM, 1989, HRC-J HIGH RES CHROM, V12, P28
  • [8] CAPILLARY ELECTROCHROMATOGRAPHY OF SMALL MOLECULES IN POLYACRYLAMIDE GELS WITH ELECTROOSMOTIC FLOW
    FUJIMOTO, C
    KINO, J
    SAWADA, H
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) : 107 - 113
  • [9] CAPILLARY ELECTROPHORESIS
    GORDON, MJ
    HUANG, XH
    PENTONEY, SL
    ZARE, RN
    [J]. SCIENCE, 1988, 242 (4876) : 224 - 228
  • [10] A STATIONARY-PHASE FOR OPEN-TUBULAR LIQUID-CHROMATOGRAPHY AND ELECTROCHROMATOGRAPHY USING SOL-GEL TECHNOLOGY
    GUO, Y
    COLON, LA
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (15) : 2511 - 2516