Uniformity of ionization response of structurally diverse analytes using a chip-based nanoelectrospray ionization source

被引:41
作者
Hop, CECA [1 ]
Chen, Y [1 ]
Yu, LJ [1 ]
机构
[1] Pfizer Global Res & Dev, Dept Pharmacokinet Dynam & Metab, Groton, CT 06340 USA
关键词
D O I
10.1002/rcm.2182
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The major drawback of liquid chromatography/mass spectrometry (LC/MS) for the analysis of mixtures is the non-quantitative nature of these studies. The ionization efficiency of the various components in the mixture (e.g., a compound and its metabolites) can vary greatly and, therefore, relative intensities of signals cannot be related to relative abundance. A chip-based nanoelectrospray ionization source was used to compare the ionization efficiencies of compounds with different physical-chemical characteristics. The data indicate that the ionization efficiencies vary much less with the chip-based device than by LC/MS. This was ascribed to the generation of a much higher electric field around the nozzles, which supplies a large excess of protons to the small droplets and reduces/eliminates the differences in the ionization efficiency for the analytes. Copyright (C) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:3139 / 3142
页数:4
相关论文
共 19 条
[1]  
Baillie TA, 2000, MASS SPECTROMETRY IN BIOLOGY & MEDICINE, P481
[2]  
BORTS DJ, 2004, P 52 ASMS C MASS SPE
[3]   Demonstration of direct bioanalysis of drugs in plasma using nanoelectrospray infusion from a silicon chip coupled with tandem mass spectrometry [J].
Dethy, JM ;
Ackermann, BL ;
Delatour, C ;
Henion, JD ;
Schultz, GA .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :805-811
[4]   In vitro metabolite identification using fast gradient high performance liquid chromatography combined with tandem mass spectrometry [J].
Hop, CECA ;
Tiller, PR ;
Romanyshyn, L .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (03) :212-219
[5]   Nanoelectrospray -: More than just a minimized-flow electrospray ionization source [J].
Juraschek, R ;
Dülcks, T ;
Karas, M .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (04) :300-308
[6]   Quantitation of midazolam in human plasma by automated chip-based infusion nanoelectrospray tandem mass spectrometry [J].
Kapron, JT ;
Pace, E ;
Van Pelt, CK ;
Henion, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (18) :2019-2026
[7]   HPLC-API/MS/MS: a powerful tool for integrating drug metabolism into the drug discovery process [J].
Korfmacher, WA ;
Cox, KA ;
Bryant, MS ;
Veals, J ;
Ng, K ;
Watkins, R ;
Lin, CC .
DRUG DISCOVERY TODAY, 1997, 2 (12) :532-537
[8]  
LEE MS, 2002, LC MS APPL DRUG DEV
[9]  
Prakash C, 1997, DRUG METAB DISPOS, V25, P863
[10]  
Prakash C, 1997, DRUG METAB DISPOS, V25, P897