Performance characteristics of micro crystal element (MiCE) detectors

被引:57
作者
Miyaoka, RS [1 ]
Kohlmyer, SG
Lewellen, TK
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[2] Gen Elect, Med Syst, Waukesha, WA 98195 USA
关键词
high-resolution positron emission tomography; (PET) detectors; small animal PET;
D O I
10.1109/23.958366
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two micro crystal element (MiCE) detector unit designs are evaluated. The detector units are built using highly packed arrays of 0.8 x 0.8 x 6 mm mixed lutetium silicate (MLS) crystals. The first detector unit, MiCE1, consists of a 5 x 5 array of 0.8 mm x 0.8 mm x 6 turn MLS crystals. The detector unit is coupled to four channels of a Hamamatsu multichannel photomultiplier tube (PMT) via a 2 x 2 array of 2 mm x 2 min square optical fibers. The crystal of interaction is determined using simple Anger style logic. Light is shared within the crystal array to help facilitate decoding of the crystals. A full detector module will consist of a 4 x 4 array of detector units coupled to a 64-channel PMT. The second detector unit, MiCE2, consists of an array of 0.8 mm x 0.8 mm x 6 mm MLS crystals directly coupled to a 6 + 6 cross-anode PMT. The crystal of interaction is determined using simple Anger style logic. In both designs, individual crystals are well visualized. Simulations were performed to determine the imaging characteristics of a detector system consisting of MiCE1 detector modules (12.8-cm ring diameter). Results indicate that a detector system built with our MiCE detectors will have an image resolution of less than I mm for the central 2 cm of the field of view.
引用
收藏
页码:1403 / 1407
页数:5
相关论文
共 6 条
[1]   A MULTICRYSTAL 2-DIMENSIONAL BGO DETECTOR SYSTEM FOR POSITRON EMISSION TOMOGRAPHY [J].
CASEY, ME ;
NUTT, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :460-463
[2]  
Chatziioannou AF, 1999, J NUCL MED, V40, P1164
[3]  
HARRISON RL, 1993, IEEE NUCL SCI S, P1154
[4]   CERIUM-DOPED LUTETIUM OXYORTHOSILICATE - A FAST, EFFICIENT NEW SCINTILLATOR [J].
MELCHER, CL ;
SCHWEITZER, JS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :502-505
[5]   Effect of detector scatter on the decoding accuracy of a DOT detector module [J].
Miyaoka, RS ;
Lewellen, TK .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) :1614-1619
[6]   Giant birefringent optics in multilayer polymer mirrors [J].
Weber, MF ;
Stover, CA ;
Gilbert, LR ;
Nevitt, TJ ;
Ouderkirk, AJ .
SCIENCE, 2000, 287 (5462) :2451-2456