Estimating black-level emissions of computer-controlled displays

被引:21
作者
Berns, RS [1 ]
Fernandez, SR [1 ]
Taplin, L [1 ]
机构
[1] Rochester Inst Technol, Chester F Carlson Ctr Imaging Sci, Munsell Color Sci Lab, Rochester, NY 14623 USA
关键词
display colorimetry; device colorimetric characterization; color profiles;
D O I
10.1002/col.10181
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
It is quite common for computer-controlled displays to emit light in image areas set to digital values of zero, referred to as their black level. This is expected for liquid-crystal displays and also can occur for cathode-ray tube displays when the "brightness" (gun-amplifier offset) is set excessively high. For either display, the light emission at the black level results in color channels whose chromaticities vary with luminance level. Consequently, typical methods of colorimetric characterization result in large error. When this black-level emission is measured and accounted for suitably, characterization accuracy is dramatically improved. Unfortunately, many instruments used to measure displays have too low a sensitivity to measure black-level emission with sufficient precision and accuracy. A method of estimating black-level emissions was derived and tested. Because the optimal black-level results in channel chromaticities that are invariant to the greatest extent with luminance level, an objective function was defined as the sum of chromaticity variances of each channel over a range of measurements. Minimizing this objective function resulted is an estimate of a display's black level. The estimated black level resulted in equivalent or superior performance to direct measurements. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:379 / 383
页数:5
相关论文
共 13 条
[1]  
[Anonymous], 1996, CIE PUBL, V122
[2]   Methods for characterizing CRT displays [J].
Berns, RS .
DISPLAYS, 1996, 16 (04) :173-182
[3]   CRT COLORIMETRY .1. THEORY AND PRACTICE [J].
BERNS, RS ;
MOTTA, RJ ;
GORZYNSKI, ME .
COLOR RESEARCH AND APPLICATION, 1993, 18 (05) :299-314
[4]   CRT COLORIMETRY .2. METROLOGY [J].
BERNS, RS ;
GORZYNSKI, ME ;
MOTTA, RJ .
COLOR RESEARCH AND APPLICATION, 1993, 18 (05) :315-325
[5]  
Berns RS, 2000, BILLMEYER SALTZMANS
[6]  
Fairchild M.D., 1998, COLORIMETRIC CHARACT
[7]  
Gibson J. E., 2000, COLORIMETRIC CHARACT
[8]  
*IEC, 2000, 619663 IEC
[9]   An accurate characterization of CRT monitor (II) proposal for an extension to CIE method and its verification [J].
Katoh, N ;
Deguchi, T ;
Berns, RS .
OPTICAL REVIEW, 2001, 8 (05) :397-408
[10]   An accurate characterization of CRT monitor (I) verifications of past studies and clarifications of gamma [J].
Katoh, N ;
Deguchi, T ;
Berns, RS .
OPTICAL REVIEW, 2001, 8 (05) :305-314