Detection of glutamate in the human brain at 3 T using optimized constant time point resolved spectroscopy

被引:49
作者
Mayer, D [1 ]
Spielman, DM [1 ]
机构
[1] Stanford Univ, Dept Radiol, Lucas MRS Imaging Ctr, Stanford, CA 94305 USA
关键词
H-1; MRS; effective homonuclear decoupling; glutamate; brain metabolites; j-coupling;
D O I
10.1002/mrm.20571
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A CT-PRESS sequence was implemented on a 3-T MR scanner and optimized for the detection of the C4 resonance of glutamate. By simulating the sequence using the full density matrix it was found that 121 chemical shift encoding steps in t(1) with an increment Delta t(1) = 1.6 ms were sufficient to separate the glutamate C4 resonance. The simulations also showed that the highest signal-to-noise ratio was achieved at an average echo time of 131 ms. When using an eightfold undersampling scheme in f(1) in order to reduce the minimum total measurement time, the average echo time was 139 ms with 17 encoding steps (At, = 12.8 ms). The sequence was tested on phantoms containing solutions of various brain metabolites and on healthy human volunteers. Besides resolving glutamate, other resonances detected in vivo comprised N-acetyl aspartate, total creatine, choline containing compounds, and myo-inositol. However, glutamine resonances could not be resolved due to severe signal overlap from glutamate and N-acetyl aspartate.
引用
收藏
页码:439 / 442
页数:4
相关论文
共 22 条
[1]   INVESTIGATION OF COMPLEX NETWORKS OF SPIN-SPIN COUPLING BY TWO-DIMENSIONAL NMR [J].
BAX, A ;
FREEMAN, R .
JOURNAL OF MAGNETIC RESONANCE, 1981, 44 (03) :542-561
[2]   Detection of homonuclear decoupled in vivo proton NMR spectra using constant time chemical shift encoding: CT-PRESS [J].
Dreher, W ;
Leibfritz, D .
MAGNETIC RESONANCE IMAGING, 1999, 17 (01) :141-150
[3]   ON THE USE OF 2-DIMENSIONAL-J NMR MEASUREMENTS FOR IN-VIVO PROTON MRS - MEASUREMENT OF HOMONUCLEAR DECOUPLED SPECTRA WITHOUT THE NEED FOR SHORT ECHO TIMES [J].
DREHER, W ;
LEIBFRITZ, D .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :331-337
[4]  
DREHER W, 1998, P 6 ANN M ISMRM SYDN, P357
[5]   Integrated RF coil with stabilization for fMRI human cortex [J].
Fitzsimmons, JR ;
Scott, JD ;
Peterson, DM ;
Wolverton, BL ;
Webster, CS ;
Lang, PJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (01) :15-18
[6]  
Govindaraju V, 2000, NMR BIOMED, V13, P129, DOI 10.1002/1099-1492(200005)13:3<129::AID-NBM619>3.0.CO
[7]  
2-V
[8]   Measurement of brain glutamate using TE-averaged PRESS at 3T [J].
Hurd, R ;
Sailasuta, N ;
Srinivasan, R ;
Vigneron, DB ;
Pelletier, D ;
Nelson, SJ .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (03) :435-440
[9]   Glutamate-mediated excitotoxicity and neurodegeneration in Alzheimer's disease [J].
Hynd, MR ;
Scott, HL ;
Dodd, PR .
NEUROCHEMISTRY INTERNATIONAL, 2004, 45 (05) :583-595
[10]  
MAYER D, 2004, P 12 ANN M ISMRM KYO, P678