Correcting organ motion artifacts in x-ray CT medical imaging systems by adaptive processing. I. Theory

被引:17
作者
Dhanantwari, AC
Stergiopoulos, S
Iakovidis, I
机构
[1] Def & Civil Inst Environm Med, Biomed Sci Sect, Toronto, ON M3M 3B9, Canada
[2] Univ Western Ontario, Dept Elect & Comp Engn, London, ON N6A 5B9, Canada
[3] Commiss European Communities, DG IST, B-1160 Brussels, Belgium
关键词
CT scanners; ogan motion artifacts; spatial overlap correlator; adaptive interference canceller;
D O I
10.1118/1.1388892
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
X-ray CT scanners provide images of transverse cross sections of the human body from a large number of projections. During the data acquisition process, which usually takes about 1 s, motion effects such as respiration, cardiac motion, and patient restlessness produce artifacts that appear as blurring, doubling, and distortion in the reconstructed images, and may lead to inaccurate diagnosis. To address this problem several processing techniques have been proposed that require a priori knowledge of the motion characteristics. This paper proposes a method, which makes no assumptions about the properties of the motion, to eliminate the motion artifacts. The approach in this paper uses a spatial overlap correlator scheme to accurately track organ motion in computed tomography imaging systems. Then, it is shown that as optimum processing scheme to remove organ motion effects is to apply adaptive interference cancellation (AIC) methods, which treat the output of the spatial overlap correlator as noise interference at the input of the AIC process. Furthermore, an AIC method does not require any kind of periodicity of the motion effects. Synthetic data tests demonstrate the validity of this approach and show that hardware modifications are essential for its implementation in x-ray CT medical imaging systems. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:1562 / 1576
页数:15
相关论文
共 18 条
[1]   EFFECTS OF BIOLOGICAL MOTION ON CT RESOLUTION [J].
ALFIDI, RJ ;
MACINTYRE, WJ ;
HAAGA, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1976, 127 (01) :11-15
[2]  
CHIU YH, 1994, P IEEE C ASSP AD, V1, pV309
[3]   Respiratory compensation in projection imaging using a magnification and displacement model [J].
Crawford, CR ;
King, KF ;
Ritchie, CJ ;
Godwin, JD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (03) :327-332
[4]   Correcting organ motion artifacts in x-ray CT systems based on tracking of motion phase by the spatial overlap correlator. II. Experimental study [J].
Dhanantwari, AC ;
Stergiopoulos, S ;
Zamboglou, N ;
Baltas, D ;
Vogt, HG ;
Karangelis, G .
MEDICAL PHYSICS, 2001, 28 (08) :1577-1596
[5]  
DHANANTWARI AC, 1998, ICSPAT 98 C P, V1, P16
[6]  
DHANANTWARI AC, 1999, THESIS U W ONTARIO O
[7]   PROBLEMS AND PITFALLS IN THE EVALUATION OF THORACIC AORTIC DISSECTION BY COMPUTED-TOMOGRAPHY [J].
GODWIN, JD ;
BREIMAN, RS ;
SPECKMAN, JM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (04) :750-756
[8]   AN ALTERNATIVE APPROACH TO LINEARLY CONSTRAINED ADAPTIVE BEAMFORMING [J].
GRIFFITHS, LJ ;
JIM, CW .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1982, 30 (01) :27-34
[9]   MOTION ARTIFACT CORRECTION IN MRI USING GENERALIZED PROJECTIONS [J].
HEDLEY, M ;
HONG, Y ;
ROSENFELD, D .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (01) :40-46
[10]  
Kak AC, 1984, DIGITAL IMAGE PROCES