Correcting organ motion artifacts in x-ray CT systems based on tracking of motion phase by the spatial overlap correlator. II. Experimental study

被引:13
作者
Dhanantwari, AC
Stergiopoulos, S
Zamboglou, N
Baltas, D
Vogt, HG
Karangelis, G
机构
[1] Def & Civil Inst Environm Med, Toronto, ON M3M 3B9, Canada
[2] Univ Western Ontario, Dept Elect & Comp Engn, London, ON N6A 5B9, Canada
[3] Stadt Kliniken Offenbach, Strahlenklin, D-63069 Offenbach, Germany
[4] Fraunhofer Inst Comp Graph, IGD, D-64283 Darmstadt, Germany
关键词
x-ray CT systems; imaging coronary calcification; retrospective gating; spatial overlap correlator; cardiac motion artifacts;
D O I
10.1118/1.1388893
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper presents the experimental part of an investigation on tracking and eliminating organ motion artifacts in x-ray CT cardiac applications with emphasis on imaging coronary calcification. The system methodology consists of a software implementation of the spatial overlap correlator (SSOC) concept in x-ray CT scanners to track the net amplitude and phase of organ motion during the CT data acquisition process. A coherent sinogram synthesis (CSS) method is then used to identify the repeated phases of a periodic organ motion from the information provided by the SSOC process and hence synthesize a new sinogram with no motion effects. Since the SSOC scheme is capable of tracking cardiac motion, it identifies also the projection points associated with minimum amplitude cardiac motion effects. These points are used to identify a 180 degrees plus the fan angle sino,gram for image reconstruction. This leads to a retrospective gating (RG) scheme that is based on the output of the SSOC process. Performance comparison of the proposed methodology with the retrospective ECG gating using real data sets with phantoms and human patients provides a performance assessment of the merits of the proposed methods. Real results demonstrate that the new methodology eliminates the requirement for ECG gating. Moreover, the CSS and the new RG methods do not require breath holding and they can be implemented in x-ray CT scanners to image coronary calcification and the heart's ventricles. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:1577 / 1596
页数:20
相关论文
共 8 条
[1]  
DHANANRWARI A, 1999, THESIS U W ONTARIO O
[2]   Correcting organ motion artifacts in x-ray CT medical imaging systems by adaptive processing. I. Theory [J].
Dhanantwari, AC ;
Stergiopoulos, S ;
Iakovidis, I .
MEDICAL PHYSICS, 2001, 28 (08) :1562-1576
[3]  
Foley J. D., 1990, Computer Graphics, Principles and Practice, V2nd
[4]   Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart [J].
Kachelriess, M ;
Kalender, WA .
MEDICAL PHYSICS, 1998, 25 (12) :2417-2431
[5]   CARDIAC COMPUTED-TOMOGRAPHY USING REDUNDANT-RAY PROSPECTIVE GATING [J].
MOORE, SC ;
JUDY, PF .
MEDICAL PHYSICS, 1987, 14 (02) :193-196
[6]   PROSPECTIVELY GATED CARDIAC COMPUTED-TOMOGRAPHY [J].
MOORE, SC ;
JUDY, PF ;
GARNIC, JD ;
KAMBIC, GX ;
BONK, F ;
COCHRAN, G ;
MARGOSIAN, P ;
MCCROSKEY, W ;
FOOTE, F .
MEDICAL PHYSICS, 1983, 10 (06) :846-855
[7]   GATED CARDIAC COMPUTED-TOMOGRAPHY WITH A MOTION PHANTOM [J].
MOREHOUSE, CC ;
BRODY, WR ;
GUTHANER, DF ;
BREIMAN, RS ;
HARELL, GS .
RADIOLOGY, 1980, 134 (01) :213-217
[8]  
Oppenheim A., 1983, SIGNALS SYSTEMS