Calibration of serum creatinine in the National Health and Nutrition Examination Surveys (NHANES) 1988-1994, 1999-2004

被引:274
作者
Selvin, Elizabeth [1 ,2 ]
Manzi, Jane [2 ]
Stevens, Lesley A. [3 ]
Van Lente, Frederick [4 ]
Lacher, David A. [5 ]
Levey, Andrew S. [3 ]
Coresh, Josef [1 ,2 ]
机构
[1] Johns Hopkins Univ, Welch Ctr Prevent Epidemiol & Clin Res, Baltimore, MD 21287 USA
[2] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Epidemiol, Baltimore, MD 21218 USA
[3] Tufts Univ New England Med Ctr, Div Nephrol, Boston, MA USA
[4] Cleveland Clin Fdn, Cleveland, OH 44195 USA
[5] Ctr Dis Control & Prevent, Natl Ctr Hlth Stat, Hyattsville, MD 20782 USA
关键词
serum creatinine; calibration; NHANES; national surveys;
D O I
10.1053/j.ajkd.2007.08.020
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: The calibration of serum creatinine values to standardized creatinine and the commutability of serum creatinine across surveys are essential to the correct use of National Health and Nutrition Examination Survey (NHANES) data for kidney function and for generating estimates of the burden of kidney disease in the United States. Study Design: Calibration study of serum creatinine in NHANES III (1988-1994) and NHANES 1999-2000, 2001-2002, and 2003-2004 to directly compare creatinine measurements from the original surveys with standard creatinine measured using an assay traceable to known gold-standard methods. We also assessed predictors of differences between methods (potential interferences) in this general population. Setting & Participants: The NHANES are ongoing cross-sectional surveys of the civilian noninstitutionalized population of the United States. We selected random samples of approximately 200 stored specimens from persons aged 60 years or older from each survey (NHANES III, 1999-2000, 2001-2002, and 2003-2004). Measurements: Stored serum specimens from the 4 NHANES surveys were analyzed for serum creatinine by using a Roche enzymatic assay implemented at the Cleveland Clinic Research Laboratory (CCRL). The Roche assay is traceable to gold-standard reference methods. The original NHANES serum creatinine values were obtained using the Jaffe method (kinetic alkaline picrate) implemented in several different laboratories. Results: Overall agreement between the original NHANES values (Jaffe method) and CCRL measurements (Roche enzymatic) was high, but substantial biases were observed in NHANES III and 1999-2000. No bias was observed in NHANES 2001-2002 and 2003-2004. Final calibration equations to correct serum creatinine values in the relevant surveys are provided. Assay differences were independent of sex, race/ethnicity, and bilirubin and triglyceride levels, but weakly related to age and glucose concentration. Limitations: We were not able to examine drift in measurements over time within each survey or directly evaluate freeze-thaw effects. Conclusions: The magnitude of differences in serum creatinine measurements in NHANES III and 1999-2000 from standard creatinine would result in large differences in estimates of kidney function (10% to 20%). Thus, correction of original creatinine values in NHANES III and 1999-2000 is essential, but no correction is needed for NHANES 2001-2002 or 2003-2004.
引用
收藏
页码:918 / 926
页数:9
相关论文
共 15 条
[1]   Calibration and random variation of the serum creatinine assay as critical elements of using equations to estimate glomerular filtration rate [J].
Coresh, J ;
Astor, BC ;
McQuillan, G ;
Kusek, J ;
Greene, T ;
Van Lente, F ;
Levey, AS .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2002, 39 (05) :920-929
[2]   Chronic kidney disease awareness, prevalence, and trends among US adults, 1999 to 2000 [J].
Coresh, J ;
Byrd-Holt, D ;
Astor, BC ;
Briggs, JP ;
Eggers, PW ;
Lacher, DA ;
Hostetter, TH .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2005, 16 (01) :180-188
[3]   EFFECT OF LONG-TERM FREEZER STORAGE, THAWING, AND REFREEZING ON SELECTED CONSTITUENTS OF SERUM [J].
DIMAGNO, EP ;
CORLE, D ;
OBRIEN, JF ;
MASNYK, IJ ;
GO, VLW ;
AAMODT, R .
MAYO CLINIC PROCEEDINGS, 1989, 64 (10) :1226-1234
[4]  
Gunter E.W., 1996, LAB PROCEDURES USED
[5]   Estimating glomerular filtration rate in the general population: the second Health Survey of Nord-Trondelag (HUNT II) [J].
Hallan, Stein ;
Astor, Brad ;
Lydersen, Stian .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 (06) :1525-1533
[6]   Using standardized serum creatinine values in the modification of diet in renal disease study equation for estimating glomerular filtration rate [J].
Levey, Andrew S. ;
Coresh, Josef ;
Greene, Tom ;
Stevens, Lesley A. ;
Lucy Zhang, Yaping ;
Hendriksen, Stephen ;
Kusek, John W. ;
Van Lente, Frederick .
ANNALS OF INTERNAL MEDICINE, 2006, 145 (04) :247-254
[7]  
Martin RF, 2000, CLIN CHEM, V46, P100
[8]  
Miller WG, 2005, ARCH PATHOL LAB MED, V129, P297
[9]   Recommendations for improving serum creatinine measurement: A report from the laboratory working group of the National Kidney Disease Education Program [J].
Myers, GL ;
Miller, WG ;
Coresh, J ;
Fleming, J ;
Greenberg, N ;
Greene, T ;
Hostetter, T ;
Levey, AS ;
Panteghini, M ;
Welch, M ;
Eckfeldt, JH .
CLINICAL CHEMISTRY, 2006, 52 (01) :5-18
[10]  
*NHANES, NHANES 1999 2000 LAB