Determination of basic degradation products of chemical warfare agents in water using hollow fibre-protected liquid-phase microextraction with in-situ derivatisation followed by gas chromatography-mass spectrometry

被引:28
作者
Lee, Hoi Sim Nancy [1 ,2 ]
Sng, Mui Tiang [2 ]
Basheer, Chanbasha [1 ]
Lee, Hian Kee [1 ]
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
[2] DSO Natl Labs, Singapore 118230, Singapore
关键词
hollow fibre; liquid-phase microextraction; silylation; chemical warfare agent degradation products; gas chromatography-mass spectrometry;
D O I
10.1016/j.chroma.2008.04.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hollow fibre-protected liquid-phase microextraction (HF-LPME) together with gas chromatography-mass spectrometry was, for the first time, investigated for the in-situ derivatisation and analysis of basic degradation products of chemical warfare agents in water samples. The degradation products studied were those of nerve and blister agents, and a psychotomimetic agent. Extractions with in-situ derivatisation were successfully performed using a mixture of solvent and derivatising agent. The protection of the moisture-sensitive derivatising agent was afforded by the hydrophobic hollow fibre. Parameters such as type of derivatising agent, extraction solvent, pH, salt concentration, stirring speed and extraction time were optimised using spiked deionised water samples. The linear range established was between 0.05 and 25 mu g ml(-1) depending on analyte, with squared regression coefficients ranging from 0.9959 to 0.9996. Relative standard deviations (RSDs) ranged from 6% to 10%. As comparison, solid-phase microextraction (SPME) was also evaluated and extraction conditions such as pH, salt concentration, stirring speed and extraction time were optimised. This work also represented the first report of such an in-situ derivatisation approach for SPME of basic analytes. The linear range established was between 0.5 and 25 mu g ml(-1) depending on analyte, with squared regression coefficients ranging from 0.9946 to 0.9998. RSDs ranged from 5% to 22%. The limits of detection of HF-LPME (0.04-0.36 mu g l(-1)) showed improvement over those of SPME (0.06-0.77 mu g l(-1)). (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 33 条
[1]   Analysis of 3-quinuclidinol derivatives by capillary electrophoresis [J].
Bednár, P ;
Barták, P ;
Lemr, K ;
Sevcík, J ;
Stránsky, Z .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (08) :709-714
[2]   Capillary electrophoresis/mass spectrometry:: a promising tool for the control of some physiologically hazardous compounds.: I -: Derivatives of 3-quinuclidinol [J].
Bednár, P ;
Lemr, K ;
Barták, P ;
Sevcík, J ;
Hlavác, J ;
Styskala, J ;
Wiedermannová, I ;
Stránsky, Z .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (12) :1213-1218
[3]   Derivatisation reactions in the chromatographic analysis of chemical warfare agents and their degradation products [J].
Black, RM ;
Muir, B .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :253-281
[4]   Application of liquid chromatography-atmospheric pressure chemical ionisation mass spectrometry, and tandem mass spectrometry, to the analysis and identification of degradation products of chemical warfare agents [J].
Black, RM ;
Read, RW .
JOURNAL OF CHROMATOGRAPHY A, 1997, 759 (1-2) :79-92
[5]  
Bosak A, 2005, CROAT CHEM ACTA, V78, P121
[6]   DETERMINATION OF 3-QUINUCLIDINYL BENZILATE (QNB) AND ITS MAJOR METABOLITES IN URINE BY ISOTOPE-DILUTION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BYRD, GD ;
PAULE, RC ;
SANDER, LC ;
SNIEGOSKI, LT ;
WHITE, E ;
BAUSUM, HT .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1992, 16 (03) :182-187
[7]   Screening of nitrogen mustards and their degradation products in water and decontamination solution by liquid chromatography-mass spectrometry [J].
Chua, HC ;
Lee, HS ;
Sng, MT .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1102 (1-2) :214-223
[8]   Postcolumn derivatization liquid chromatography mass spectrometry for detection of chemical-weapons-related compounds [J].
Creasy, WR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (05) :440-447
[9]   Hollow fiber-mediated liquid-phase microextraction of chemical warfare agents from water [J].
Dubey, DK ;
Pardasani, D ;
Gupta, AK ;
Palit, M ;
Kanaujia, PK ;
Tak, V .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1107 (1-2) :29-35
[10]  
Gresham GL, 2000, J MASS SPECTROM, V35, P1460, DOI 10.1002/1096-9888(200012)35:12<1460::AID-JMS82>3.0.CO