Determination of basic degradation products of chemical warfare agents in water using hollow fibre-protected liquid-phase microextraction with in-situ derivatisation followed by gas chromatography-mass spectrometry

被引:28
作者
Lee, Hoi Sim Nancy [1 ,2 ]
Sng, Mui Tiang [2 ]
Basheer, Chanbasha [1 ]
Lee, Hian Kee [1 ]
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
[2] DSO Natl Labs, Singapore 118230, Singapore
关键词
hollow fibre; liquid-phase microextraction; silylation; chemical warfare agent degradation products; gas chromatography-mass spectrometry;
D O I
10.1016/j.chroma.2008.04.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hollow fibre-protected liquid-phase microextraction (HF-LPME) together with gas chromatography-mass spectrometry was, for the first time, investigated for the in-situ derivatisation and analysis of basic degradation products of chemical warfare agents in water samples. The degradation products studied were those of nerve and blister agents, and a psychotomimetic agent. Extractions with in-situ derivatisation were successfully performed using a mixture of solvent and derivatising agent. The protection of the moisture-sensitive derivatising agent was afforded by the hydrophobic hollow fibre. Parameters such as type of derivatising agent, extraction solvent, pH, salt concentration, stirring speed and extraction time were optimised using spiked deionised water samples. The linear range established was between 0.05 and 25 mu g ml(-1) depending on analyte, with squared regression coefficients ranging from 0.9959 to 0.9996. Relative standard deviations (RSDs) ranged from 6% to 10%. As comparison, solid-phase microextraction (SPME) was also evaluated and extraction conditions such as pH, salt concentration, stirring speed and extraction time were optimised. This work also represented the first report of such an in-situ derivatisation approach for SPME of basic analytes. The linear range established was between 0.5 and 25 mu g ml(-1) depending on analyte, with squared regression coefficients ranging from 0.9946 to 0.9998. RSDs ranged from 5% to 22%. The limits of detection of HF-LPME (0.04-0.36 mu g l(-1)) showed improvement over those of SPME (0.06-0.77 mu g l(-1)). (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 33 条
[31]   Solid-phase microextraction of monocyclic aromatic amines using novel fibers coated with crown ether [J].
Zeng, ZR ;
Qiu, WL ;
Yang, M ;
Wei, X ;
Huang, ZF ;
Li, F .
JOURNAL OF CHROMATOGRAPHY A, 2001, 934 (1-2) :51-57
[32]   Liquid-liquid-liquid microextraction of nitrophenols with a hollow fiber membrane prior to capillary liquid chromatography [J].
Zhu, LY ;
Zhu, L ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) :407-414
[33]  
1999, SOLID PHASE MICROEXT