Limits of detection of SPIO at 3.0 T using T2* relaxometry

被引:144
作者
Dahnke, H [1 ]
Schaeffter, T [1 ]
机构
[1] Philips Res Labs, Tech Syst, D-22335 Hamburg, Germany
关键词
T-2*; relaxometry; SPIO; susceptibility; sensitivity;
D O I
10.1002/mrm.20435
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
T-2* relaxometry for quantitative MR imaging is strongly hampered by large-scale field inhomogeneities, which lead to signal losses and an overestimation of the relaxation rate R-2*. This is of particular importance for the sensitive detection of iron oxide contrast agent distributions. To derive an accurate measurement of T-2*, a main field inhomogeneity correction is applied: the main field inhomogeneity is derived from multislice T-2* relaxometry data and used as an initial value for an iterative optimization, by which the relaxation signal is corrected for each voxel. These corrected T-2* maps show reduced influence of the local field variation and contain information about the local SPIO concentration. The method was tested on phantoms and the limit of detection of SPIO labeled cells using T-2* relaxometry was estimated in volunteers to be 120 x 10(3) cells/mL (2.4 mu g Fe/mL) in the brain and 385 x 10(3) cells/mL (8 mu g Fe/mL) in the liver. Magn Reson Med 53:1202-1206, 2005. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:1202 / 1206
页数:5
相关论文
共 22 条
[1]   Cerebral oxygen extraction fraction and cerebral venous blood volume measurements using MRI: Effects of magnetic field variation [J].
An, HY ;
Lin, WL .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) :958-966
[2]   Application of the static dephasing regime theory to superparamagnetic iron-oxide loaded cells [J].
Bowen, CV ;
Zhang, XW ;
Saab, G ;
Gareau, PJ ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) :52-61
[3]   REDUCTION OF SUSCEPTIBILITY ARTIFACT IN GRADIENT-ECHO IMAGING [J].
CHO, ZH ;
RO, YM .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :193-200
[4]  
Fernández-Seara MA, 2000, MAGNET RESON MED, V44, P358, DOI 10.1002/1522-2594(200009)44:3<358::AID-MRM3>3.0.CO
[5]  
2-I
[6]   DIRECT FLASH MR IMAGING OF MAGNETIC-FIELD INHOMOGENEITIES BY GRADIENT COMPENSATION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (04) :474-480
[7]   Clinically applicable labeling of mammalian and stem cells by combining; Superparamagnetic iron oxides and transfection agents [J].
Frank, JA ;
Miller, BR ;
Arbab, AS ;
Zywicke, HA ;
Jordan, EK ;
Lewis, BK ;
Bryant, LH ;
Bulte, JWM .
RADIOLOGY, 2003, 228 (02) :480-487
[8]   HEMOCHROMATOSIS - DIAGNOSIS AND QUANTIFICATION OF LIVER IRON WITH GRADIENT-ECHO MR-IMAGING [J].
GANDON, Y ;
GUYADER, D ;
HEAUTOT, JF ;
REDA, MI ;
YAOUANQ, J ;
BUHE, T ;
BRISSOT, P ;
CARSIN, M ;
DEUGNIER, Y .
RADIOLOGY, 1994, 193 (02) :533-538
[9]  
Glover GH, 1999, MAGNET RESON MED, V42, P290, DOI 10.1002/(SICI)1522-2594(199908)42:2<290::AID-MRM11>3.0.CO
[10]  
2-N