Comparison of inversion recovery fast spin-echo (FSE) with T2-weighted fat-saturated FSE and T1-weighted MR imaging in bone marrow lesion detection

被引:29
作者
Pui, MH [1 ]
Chang, SK [1 ]
机构
[1] NATL UNIV SINGAPORE HOSP, DEPT RADIOL, SINGAPORE 117548, SINGAPORE
关键词
MR imaging; bone marrow; MR; fat suppression; rapid imaging;
D O I
10.1007/s002560050052
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To prospectively compare inversion recovery (IR) fast spin-echo (FSE) with T1-weighted spin-echo (SE) and T2-weighted chemical-shift fat-saturated (FS) FSE magnetic resonance se quences in the detection of bone marrow abnormality. Design. Twenty-nine sets of T1-weighted SE [400-640/10-20 (TR/TE)], T2-weighted FS-FSE [2400-3800/91-112/8 (TR/TE/ETL)], and IR-FSE [3700-6000/12-14/170/8 (TWTE/T1/ETL)] images were acquired with a 1.5-T magnet in 27 patients with bone marrow lesions. The visibility, margination, and extent of 41 lesions, image quality, contrast, and artifacts were qualitatively and quantitatively compared. Results. The lesions were more conspicuous on the IR-FSE than on the T1-weighted SE and T2-weighed FS-FSE images. The extent of lesions was similar for all three sequences. Image quality was better and there were fewer motion artifacts on the T1-weighted images. The mean lesion contrast-to-noise ratio was significantly higher on the T1-weighted images (p<0.05). Conclusion. The IR-FSE sequence is highly sensitive for detecting bone marrow pathology, with scan time comparable to the T1-weighted SE and T2-weighted FS-FSE sequences.
引用
收藏
页码:149 / 152
页数:4
相关论文
共 9 条
[1]
SIGNAL-TO-NOISE AND CONTRAST IN FAST SPIN-ECHO (FSE) AND INVERSION RECOVERY FSE IMAGING [J].
CONSTABLE, RT ;
SMITH, RC ;
GORE, JC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (01) :41-47
[2]
THE ROLE OF THE STIR SEQUENCE IN MAGNETIC-RESONANCE-IMAGING EXAMINATION OF BONE-TUMORS [J].
GOLFIERI, R ;
BADDELEY, H ;
PRINGLE, JS ;
SOUHAMI, R .
BRITISH JOURNAL OF RADIOLOGY, 1990, 63 (748) :251-256
[3]
FAST SPIN-ECHO INVERSION-RECOVERY IMAGING VERSUS FAST T2-WEIGHTED SPIN-ECHO IMAGING IN BONE-MARROW ABNORMALITIES [J].
HILFIKER, P ;
ZANETTI, M ;
DEBATIN, JF ;
MCKINNON, G ;
HODLER, J .
INVESTIGATIVE RADIOLOGY, 1995, 30 (02) :110-114
[4]
BONE CONTUSIONS OF THE KNEE - INCREASED LESION DETECTION WITH FAST SPIN-ECHO MR-IMAGING WITH SPECTROSCOPIC FAT-SATURATION [J].
KAPELOV, SR ;
TERESI, LM ;
BRADLEY, WG ;
BUCCIARELLI, NR ;
MURAKAMI, DM ;
MULLIN, WJ ;
JORDAN, JE .
RADIOLOGY, 1993, 189 (03) :901-904
[5]
FAST SCANNING AND FAT-SUPPRESSION MR-IMAGING OF MUSCULOSKELETAL DISORDERS [J].
MIROWITZ, SA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (06) :1147-1157
[6]
MR-IMAGING OF BONE-MARROW LESIONS - RELATIVE CONSPICUOUSNESS ON T1-WEIGHTED, FAT-SUPPRESSED T2-WEIGHTED, AND STIR IMAGES [J].
MIROWITZ, SA ;
APICELLA, P ;
REINUS, WR ;
HAMMERMAN, AM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :215-221
[7]
INVERSION-RECOVERY FAST SPIN-ECHO MR-IMAGING - EFFICACY IN THE EVALUATION OF HEAD AND NECK LESIONS [J].
PANUSH, D ;
FULBRIGHT, R ;
SZE, G ;
SMITH, RC ;
CONSTABLE, RT .
RADIOLOGY, 1993, 187 (02) :421-426
[8]
COMPARISON OF STIR AND SPIN-ECHO MR IMAGING AT 1.5T IN 45 SUSPECTED EXTREMITY TUMORS - LESION CONSPICUOUSNESS AND EXTENT [J].
SHUMAN, WP ;
PATTEN, RM ;
BARON, RL ;
LIDDELL, RM ;
CONRAD, EU ;
RICHARDSON, ML .
RADIOLOGY, 1991, 179 (01) :247-252
[9]
[No title captured]