MiraLAX Is Not as Effective as GoLytely in Bowel Cleansing Before Screening Colonoscopies

被引:48
作者
Hjelkrem, Michael [1 ]
Stengel, Joel [1 ]
Liu, Mark [1 ]
Jones, David P. [1 ]
Harrison, Stephen A. [1 ]
机构
[1] Brooke Army Med Ctr, Gastroenterol Clin, Dept Med, Div Gastroenterol, Ft Sam Houston, TX 78234 USA
关键词
Colon Cancer Screening; Colon Preparation; Colorectal Neoplasia; Cathartics; COLORECTAL-CANCER; PREPARATION QUALITY; PEG SOLUTION; TRIAL; ELECTROLYTES; IMPACT; VOLUME; BLIND;
D O I
10.1016/j.cgh.2010.11.007
中图分类号
R57 [消化系及腹部疾病];
学科分类号
100201 [内科学];
摘要
BACKGROUND & AIMS: Successful colonoscopies require good bowel preparations-poor bowel preparations can increase medical costs, rates of missed lesions, and procedure duration. The combination of polyethylene glycol (PEG) 3350 without electrolytes (MiraLAX; Schering-Plough Healthcare Products, Inc, Kenilworth, NJ) and 64 oz of Gatorade (PepsiCo, Inc, Purchase, NY) has gained popularity as a bowel preparation regimen. However, the efficacy and tolerability of this approach has not been compared with standard bowel preparations in clinical trials. We compared split-dose (PEG) 3350 with electrolytes (GoLytely; Braintree Laboratories, Inc, Braintree, MA) with split-dose MiraLAX alone and in combination with pretreatment medications (bisacodyl or lubiprostone) to determine the efficacy and patient tolerability of MiraLAX as an agent for bowel preparation. METHODS: We performed a prospective, randomized, blinded, controlled trial at a tertiary care center. Patients (n = 403) were randomly assigned to groups given GoLytely, MiraLAX, MiraLAX with bisacodyl (10 mg), or MiraLAX with lubiprostone (24 mu g). MiraLAX was combined with 64 oz of Gatorade. All patients were surveyed regarding preparation satisfaction and tolerability. The Ottawa bowel preparation scale was used to grade colon cleanliness. RESULTS: GoLytely was more effective at bowel cleansing (average Ottawa score, 5.1) than MiraLAX alone (average Ottawa score, 6.9) or in combination with lubiprostone (average Ottawa score, 6.8), or bisacodyl (average Ottawa score, 6.3) (P < .001). MiraLAX was associated with a trend toward longer procedure duration (P = .096). Groups given MiraLAX rated the overall experience as more satisfactory than those given GoLytely (P < .001). There were no differences between polyp detection rates (P = .346) or adverse events (P = .823). CONCLUSIONS: Split-dose MiraLAX in 64 oz of Gatorade is not as effective as 4 L split-dose GoLytely in bowel cleansing for screening colonoscopies.
引用
收藏
页码:326 / U74
页数:8
相关论文
共 21 条
[1]
[Anonymous], AM J GASTROENTEROL
[2]
A prospective study of factors that determine cecal intubation time at colonoscopy [J].
Bernstein, C ;
Thorn, M ;
Monsees, K ;
Spell, R ;
O'Connor, JB .
GASTROINTESTINAL ENDOSCOPY, 2005, 61 (01) :72-75
[3]
Cohen LB, 2009, GASTROENTEROL HEPA S, V5, P4
[4]
Predictors of nonadherence to screening colonoscopy [J].
Denberg, TD ;
Melhado, TV ;
Coombes, JM ;
Beaty, BL ;
Berman, K ;
Byers, TE ;
Marcus, AC ;
Steiner, JF ;
Ahnen, DJ .
JOURNAL OF GENERAL INTERNAL MEDICINE, 2005, 20 (11) :989-995
[5]
Comparison of reduced volume Versus four liters sulfate-free electrolyte lavage solutions for colonoscopy colon cleansing [J].
DiPalma, JA ;
Wolff, BG ;
Meagher, A ;
Cleveland, MV .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2003, 98 (10) :2187-2191
[6]
Key safety issues of bowel preparations for colonoscopy and importance of adequate hydration [J].
Dykes, Cathy ;
Cash, Brooks D. .
GASTROENTEROLOGY NURSING, 2008, 31 (01) :30-35
[7]
A randomized single-blind trial of whole versus split-dose polyethylene glycol-electrolyte solution for colonoscopy preparation [J].
El Sayed, AMA ;
Kanafani, ZA ;
Mourad, FH ;
Soweid, AM ;
Barada, KA ;
Adorian, CS ;
Nasreddine, WA ;
Sharara, AI .
GASTROINTESTINAL ENDOSCOPY, 2003, 58 (01) :36-40
[8]
Randomized trial of low-volume PEG solution versus standard PEG plus electrolytes for bowel cleansing before colonoscopy [J].
Ell, Christian ;
Fischbach, Wolfgang ;
Bronisch, Hans-Joachim ;
Dertinger, Stefan ;
Layer, Peter ;
Ruenzi, Michael ;
Schneider, Thomas ;
Kachel, Guenther ;
Grueger, Joerg ;
Koellinger, Michael ;
Nagell, Waltraud ;
Goerg, Karl-Josel ;
Wanitschke, Roland ;
Gruss, Hans-Juergen .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2008, 103 (04) :883-893
[9]
Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study [J].
Froehlich, F ;
Wietlisbach, V ;
Gonvers, JJ ;
Burnand, B ;
Vader, JP .
GASTROINTESTINAL ENDOSCOPY, 2005, 61 (03) :378-384
[10]
Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia [J].
Harewood, GC ;
Sharma, VK ;
de Garmo, P .
GASTROINTESTINAL ENDOSCOPY, 2003, 58 (01) :76-79