Short-term wear of Japanese highly cross-linked polyethylene in cementless THA

被引:14
作者
Miyanishi, Keita [1 ]
Hara, Toshihiko [1 ]
Kaminomachi, Shigekazu [2 ]
Maekawa, Masayuki [3 ]
Iwamoto, Mikio [4 ]
Torisu, Takehiko [1 ]
机构
[1] Kyushu Rosai Hosp, Dept Orthopaed Surg, Kokuraminami Ku, Kitakyushu, Fukuoka 8000296, Japan
[2] Kyushu Cent Hosp, Dept Orthopaed Surg, Fukuoka, Japan
[3] Maekawa Rheumatol & Orthopaed Clin, Kitakyushu, Fukuoka, Japan
[4] Japan Med Mat Corp, Div Res, Osaka, Japan
关键词
wear; highly cross-linked polyethylene; THA; hip;
D O I
10.1007/s00402-007-0544-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Production of polyethylene wear from acetabular liners is thought, in part, to mediate the periprosthetic osteolysis. This study examined the in vivo wear performance of Japanese highly cross-linked polyethylene (Aeonian) in cementless total hip arthroplasty. Matherials and methods Ninety-five hips received a highly cross-linked polyethylene liner, while 20 hips were implanted with conventional polyethylene. Two-dimensional linear wear was measured on radiographs and volumetric wear was then calculated. Both linear and volumetric wear rates were examined for the 1-year postoperative period as well as for the time frame beginning after 1 year ending with the final follow-up. Results The amount of linear wear was significantly lower in the cross-linked group at 3 and 5 years postoperatively (P < 0.01 and < 0.001, respectively). Linear and volumetric wear rates after 1 year postoperatively for hips with the cross-linked polyethylene were significantly reduced by 57 and 59%, respectively, when compared to rates for those who received conventional polyethylene (P < 0.01). A multiple logistic regression analysis revealed that cross-linking was a significant factor influencing linear wear rate after 1 year postoperatively with an odds ratio, exp(ss) = 10.033 (P < 0.001). Conclusion These results suggest that the highly cross-linked polyethylene reduces penetration of the femoral head and may be an optimal bearing surface for patients receiving total hip arthroplasty.
引用
收藏
页码:995 / 1000
页数:6
相关论文
共 28 条
[1]
Five-year experience with Crossfire® highly cross-linked polyethylene [J].
D'Antonio, JA ;
Manley, MT ;
Capello, WN ;
Bierbaum, BE ;
Ramakrishnan, R ;
Naughton, M ;
Sutton, K .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) :143-150
[2]
DEVANE PA, 1999, CLIN ORTHOP RELAT R, V369, P59
[3]
DIGAS G, 2003, CLIN ORTHOP RELAT R, V417, P126
[4]
A literature review of the association between wear rate and osteolysis in total hip arthroplasty [J].
Dumbleton, JH ;
Manley, MT ;
Edidin, AA .
JOURNAL OF ARTHROPLASTY, 2002, 17 (05) :649-661
[5]
GOODMAN SB, 1998, CLIN ORTHOP RELAT R, V352, P25
[6]
GOODMAN SB, 2005, CLIN ORTHOP RELAT R, V430, P39
[7]
FEMORAL COMPONENT LOOSENING USING CONTEMPORARY TECHNIQUES OF FEMORAL CEMENT FIXATION [J].
HARRIS, WH ;
MCCARTHY, JC ;
ONEILL, DA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (07) :1063-1067
[8]
Alumina ceramic-on-ceramic total hip replacement with a layered acetabular component [J].
Hasegawa, M. ;
Sudo, A. ;
Uchida, A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (07) :877-882
[9]
Short-term in vivo wear of cross-linked polyethylene [J].
Heisel, C ;
Silva, M ;
dela Rosa, MA ;
Schmalzried, TP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (04) :748-751
[10]
Heisel Christian, 2004, Instr Course Lect, V53, P49