High-throughput microfabricated CE/ESI-MS: Automated sampling from a microwell plate

被引:105
作者
Zhang, BL
Foret, F [1 ]
Karger, BL
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Chem, Boston, MA 02115 USA
关键词
D O I
10.1021/ac001432v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new design for high-throughput microfabricated capillary electrophoresis/electrospray mass spectrometry (CE/ ESI-MS) with automated sampling from a microwell plate is presented. The approach combines a sample-loading port, a separation channel, and a liquid junction, the latter for coupling the device to the R IS with a miniaturized subatmospheric electrospray interface. The microdevice was attached to a polycarbonate manifold with external electrode reservoirs equipped for electrokinetic and pressure-fluid control. A computer-activated electropneumatic distributor was used for both sample loading from the microwell plate and washing of channels after each run. Removal of the electrodes and sample reservoirs from the microdevice structure significantly simplified the chip design and eliminated the need both for drilling access holes and for sample/buffer reservoirs. The external manifold also allowed the use of relatively large reservoirs that are necessary for extended time operation of the system. Initial results using this microfabricated system for the automated CE/ESI-MS analysis of peptides and protein digests are presented.
引用
收藏
页码:2675 / 2681
页数:7
相关论文
共 26 条
[1]   Microfluidic devises connected to fused-silica capillaries with minimal dead volume [J].
Bings, NH ;
Wang, C ;
Skinner, CD ;
Colyer, CL ;
Thibault, P ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3292-3296
[2]   Automated high-throughput infusion ESI-MS with direct coupling to a microtiter plate [J].
Felten, C ;
Foret, F ;
Minarik, M ;
Goetzinger, W ;
Karger, BL .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1449-1454
[3]   Protein identification by capillary zone electrophoresis/microelectrospray ionization-tandem mass spectrometry at the subfemtomole level [J].
Figeys, D ;
vanOostveen, I ;
Ducret, A ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1996, 68 (11) :1822-1828
[4]   Nanoflow solvent gradient delivery from a microfabricated device for protein identifications by electrospray ionization mass spectrometry [J].
Figeys, D ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3721-3727
[5]  
Foret F, 2000, ELECTROPHORESIS, V21, P1363, DOI 10.1002/(SICI)1522-2683(20000401)21:7<1363::AID-ELPS1363>3.3.CO
[6]  
2-L
[7]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[8]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[9]  
HU P, 2000, 48 ASMS C MASS SPECT
[10]   EFFECTS OF INJECTION SCHEMES AND COLUMN GEOMETRY ON THE PERFORMANCE OF MICROCHIP ELECTROPHORESIS DEVICES [J].
JACOBSON, SC ;
HERGENRODER, R ;
KOUTNY, LB ;
WARMACK, RJ ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :1107-1113