Anisotropy functions for 125I and 103Pd sources

被引:62
作者
Weaver, K [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
关键词
anisotropy function; brachytherapy; iodine; palladium;
D O I
10.1118/1.598458
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The anisotropy function was defined by AAPM Task Group 43 in a recent report, and reference data were provided. However, some of the data appeared to have large experimental errors. in this work, anisotropy functions are presented for three low-energy photon-emitting sources commonly used for brachytherapy: I-125 source models 6702 and 6711, and the model 200 Pd-103 source. The data were generated via a two-step process: the sources' intrinsic radiation emission pattern was determined from in-air measurements, and these data were used as input to Monte Carlo calculations of the fluence distribution in water. The new anisotropy function values for iodine compare well with earlier data from diode measurements, and seem more physically realistic than some data provided by TG43. Previous palladium data measured with TLDs are more variable, but on the average are similar to the data presented here. The new data have estimated uncertainties of 3%-6%; this level of accuracy should be completely adequate for clinical calculations. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)00412-X].
引用
收藏
页码:2271 / 2278
页数:8
相关论文
共 11 条
[1]
Browne E., 1986, Table of Radioactive Isotopes
[2]
THERMOLUMINESCENT DOSIMETRY FOR PD-103 SEEDS (MODEL 200) IN SOLID WATER PHANTOM [J].
CHIUTSAO, ST ;
ANDERSON, LL .
MEDICAL PHYSICS, 1991, 18 (03) :449-452
[3]
PHYSICAL DOSIMETRY OF I-125 SEEDS OF A NEW DESIGN FOR INTERSTITIAL IMPLANT [J].
LING, CC ;
YORKE, ED ;
SPIRO, IJ ;
KUBIATOWICZ, D ;
BENNETT, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (11) :1747-1752
[4]
TWO-DIMENSIONAL DOSE DISTRIBUTION OF I125 SEEDS [J].
LING, CC ;
SCHELL, MC ;
YORKE, ED ;
PALOS, BB ;
KUBIATOWICZ, DO .
MEDICAL PHYSICS, 1985, 12 (05) :652-655
[5]
MEIGOONI AS, 1990, ENDOCURIETHER HYPERT, V6, P107
[6]
ANISOTROPY FUNCTIONS FOR PD-103, I-125, AND IR-192 INTERSTITIAL BRACHYTHERAPY SOURCES [J].
NATH, R ;
MEIGOONI, AS ;
MUENCH, P ;
MELILLO, A .
MEDICAL PHYSICS, 1993, 20 (05) :1465-1473
[7]
DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43 [J].
NATH, R ;
ANDERSON, LL ;
LUXTON, G ;
WEAVER, KA ;
WILLIAMSON, JF ;
MEIGOONI, AS .
MEDICAL PHYSICS, 1995, 22 (02) :209-234
[8]
Nelson W.R., 1985, EGS4 CODE SYSTEM
[9]
DOSE DISTRIBUTIONS OF MODEL 6702 I-125 SEEDS IN WATER [J].
SCHELL, MC ;
LING, CC ;
GROMADZKI, ZC ;
WORKING, KR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (05) :795-799
[10]
A source model for efficient brachytherapy computations with Monte Carlo [J].
Weaver, K ;
Siantar, CH ;
Chandler, W ;
White, RM .
MEDICAL PHYSICS, 1996, 23 (12) :2079-2084