Use of a multilayer printed circuit board as the position sensing electrode in an MWPC

被引:8
作者
Barbosa, AF
机构
[1] Ctro. Bras. de Pesq. Físicas, CEP 22290-180, Rio de Janeiro/RJ, Rua Dr. Xavier Sigaud
关键词
D O I
10.1016/0168-9002(95)01012-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
X-ray gas position sensitive detector (PSD) is described. The detector makes use of a single electrode, the X&Y cathode, to sense the electric charge induced by the avalanches generated after the absorption of X-ray photons in a multiwire proportional counter (MWPC). Two-dimensional (2D) localization of photons is achieved by associating one delay line to each coordinate. The delay lines are directly coupled to the X&Y cathode, so that the propagation time of electric pulses can be related to the corresponding avalanche position. Since the position encoding does not involve wires, the anode is the only wire electrode present in the detector, used for collecting the avalanche electrons.
引用
收藏
页码:368 / 374
页数:7
相关论文
共 11 条
[11]  
VERDUGO JE, 1992, LNLS