GC analysis of human breath with a series-coupled column ensemble and a multibed sorption trap

被引:101
作者
Sanchez, JM [1 ]
Sacks, RD [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
关键词
D O I
10.1021/ac020725g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The combination of a tandem column ensemble and an on-line microsorption trap is used for the analysis of organic compounds in human breath samples. The four-bed sorption trap uses a series of discreet sorption beds containing three grades of graphitized carbon and a carbon molecular sieve to quantitatively remove most organic compounds from 0.8-L breath samples. The trap is then heated to 300 degreesC in similar to 1.5 s and maintained at this temperature for 10 s. The resulting vapor plug width is in the range 0.7-1.3 s for the compounds found in the breath samples. The separation is performed with a 15-m-long, 0.25-mm-i.d. capillary using a 0.5-mum-thick film of nonpolar dimethyl polysiloxane coupled in series to a polar column, either trifluoropropylmethyl polysiloxane or poly(ethylene glycol). Both column combinations are successful in separating the early-eluting compounds acetone, isoprene, pentane, methyl alcohol, and ethyl alcohol, which are all common in breath samples. The poly(ethylene glycol) combination gave better separation but showed relatively fast deterioration for repeated analysis of wet samples. Breath samples were obtained under different conditions (smoker, nonsmoker, gum chewer), and 25 compounds were identified in the various samples. Many additional peaks are observed but not identified. Analytical curves (log-log) of peak area versus sample volume for test compounds are linear in the range 80-800 cm(3). Detection limits (3sigma) for several volatile compounds in 800-cm(3) samples are in the 1-5 ppb range.
引用
收藏
页码:2231 / 2236
页数:6
相关论文
共 34 条
[1]  
AMIRAV A, 2002, P 25 INT S CAP CHROM
[2]   Stability of reactive low boiling hydrocarbons on carbon based adsorbents typically used for adsorptive enrichment and thermal desorption [J].
Dettmer, K ;
Knobloch, T ;
Engewald, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (01) :70-78
[3]   Anthropogenic volatile organic compounds in ambient air and natural waters: a review on recent developments of analytical methodology, performance and interpretation of field measurements [J].
Dewulf, J ;
Van Langenhove, H .
JOURNAL OF CHROMATOGRAPHY A, 1999, 843 (1-2) :163-177
[4]  
DUBOWSKI KM, 1974, CLIN CHEM, V20, P966
[5]   Quantitative analysis by gas chromatography of volatile carbonyl compounds in expired air from mice and human [J].
Ebeler, SE ;
Clifford, AJ ;
Shibamoto, T .
JOURNAL OF CHROMATOGRAPHY B, 1997, 702 (1-2) :211-215
[6]  
ELLER PM, 1994, DHHS NIOSH PUBLICATI
[7]  
Feng CH, 2000, J MICROCOLUMN SEP, V12, P267, DOI 10.1002/(SICI)1520-667X(2000)12:4<267::AID-MCS11>3.0.CO
[8]  
2-B
[9]   Two-stage microtrap as an injection device for continuous on-line gas chromatographic monitoring [J].
Feng, CH ;
Mitra, S .
JOURNAL OF CHROMATOGRAPHY A, 1998, 805 (1-2) :169-176
[10]   Human breath emissions of VOCs [J].
Fenske, JD ;
Paulson, SE .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1999, 49 (05) :594-598