Leakage of fluid around high-volume, low-pressure cuffs - A comparison of four tracheal tubes

被引:29
作者
Asai, T [1 ]
Shingu, K [1 ]
机构
[1] Kansai Med Univ, Dept Anaesthesiol, Moriguchi, Osaka 5708507, Japan
关键词
equipment; tracheal tube; complications; aspiration;
D O I
10.1046/j.1365-2044.2001.01718.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We studied the ability of high-volume, low-pressure tracheal tube cuffs (Portex Soft Seal(R), Portex Profile(R), Mallinckrodt Lo-Contour(R) and Mallinckrodt Hi-Lo(R) tubes) to prevent leakage of fluid into the airway, in a model trachea and lung. Five tubes (7.0 and 8.0 mm internal diameter) of each type were used. Each tube was inserted into the model trachea and the cuff inflated until the intracuff pressure reached either 20, 30 or 40 cmH(2)O. The model lung was ventilated with a tidal volume of 700 ml and respiratory rate of 14 breath.min(-1) at a compliance of 20 cmH(2)O. Ten millilitres of 0.01% methylene blue solution were infused over the cuff and the volume of fluid leaking past the cuff over 5 min was measured. The leak volume for the Soft Seal tube was less than that for the Profile or Lo-Contour tubes at all intracuff pressures (all p < 0.05). Compared with the Hi-Lo tube, the volume leaking past the cuff for the Sob Seal tube was greater at an intracuff pressure of 20 cmH(2)O (p < 0.05), whereas there was no significant difference between these two tubes at an intracuff pressure of 30 or 40 cmH(2)O. We conclude that the cuff of the Portex Soft Seal tube prevented leakage of fluid significantly more than that of the Portex Profile or Mallinckrodt Lo-Contour tubes, and to a similar degree to that of the Mallinckrodt Hi-Lo tube.
引用
收藏
页码:38 / 42
页数:5
相关论文
共 15 条
[1]  
BREATNACH E, 1984, AM J ROENTGENOL, V142, P903, DOI 10.2214/ajr.142.5.903
[2]  
DUFLOREY C, 1993, BRIT MED J, V306, P1181
[3]   LOW-PRESSURE CUFF FOR TRACHEOSTOMY TUBES TO MINIMIZE TRACHEAL INJURY - COMPARATIVE CLINICAL TRIAL [J].
GRILLO, HC ;
COOPER, JD ;
GEFFIN, B ;
PONTOPPIDAN, H .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1971, 62 (06) :898-+
[4]   DIMENSIONS OF THE GROWING TRACHEA RELATED TO AGE AND GENDER [J].
GRISCOM, NT ;
WOHL, MEB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 146 (02) :233-237
[5]   GASTRODUODENAL DYSFUNCTION AS A CAUSE OF GASTRIC BACTERIAL OVERGROWTH IN PATIENTS UNDERGOING MECHANICAL VENTILATION OF THE LUNGS [J].
INGLIS, TJJ ;
SPROAT, LJ ;
SHERRATT, MJ ;
HAWKEY, PM ;
GIBSON, JS ;
SHAH, MV .
BRITISH JOURNAL OF ANAESTHESIA, 1992, 68 (05) :499-502
[6]   Leakage of fluid around low-pressure tracheal tube cuffs [J].
Oikkonen, M ;
Aromaa, U .
ANAESTHESIA, 1997, 52 (06) :567-569
[7]   FAILURE OF A HIGH-COMPLIANCE LOW-PRESSURE CUFF TO PREVENT ASPIRATION [J].
PAVLIN, EG ;
VANNIMWEGEN, D ;
HORNBEIN, TF .
ANESTHESIOLOGY, 1975, 42 (02) :216-219
[8]  
PETRING OU, 1986, ANESTH ANALG, V65, P777
[9]   ENDOTRACHEAL CUFF PRESSURE AND TRACHEAL MUCOSAL BLOOD-FLOW - ENDOSCOPIC STUDY OF EFFECTS OF 4 LARGE VOLUME CUFFS [J].
SEEGOBIN, RD ;
VANHASSELT, GL .
BRITISH MEDICAL JOURNAL, 1984, 288 (6422) :965-968
[10]   ASPIRATION BEYOND ENDOTRACHEAL CUFFS [J].
SEEGOBIN, RD ;
VANHASSELT, GL .
CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1986, 33 (03) :273-279