Evaluation and optimization of ion-current ratio measurements by selected-ion-monitoring mass spectrometry

被引:23
作者
MacCoss, MJ
Toth, MJ
Matthews, DE
机构
[1] Univ Vermont, Dept Med, Burlington, VT 05405 USA
[2] Univ Vermont, Dept Chem, Burlington, VT 05405 USA
关键词
D O I
10.1021/ac010041t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Stable isotopically labeled compounds are regularly used as internal standards in quantitation and as tracers of in vivo metabolism. In both applications, the ratio of unlabeled to labeled analogues is determined from an ion-current ratio measured by a mass spectrometer. The precision of the ion-current ratio measurement defines the detection limit for quantitation and for tracer enrichment measurement. We have used standard models of noise to develop a method that evaluates ion-current ratio noise (i) that varies with the signal intensity and (ii) that is signal independent. This model produces a simple equation that defines the ion-current ratio precision using constants that can be evaluated empirically from the measurement of two ion-current ratios from a single standard measured multiple times. We demonstrate that our approach can predict the effect of signal intensity, ion-current ratio magnitude, and internal standard or tracer choice on the measurement precision. The standard deviations predicted by our method are shown to equal standard deviations of samples measured experimentally. This method allows a simple evaluation of a mass spectrometry system and can define the precision of new quantitation and tracer methods.
引用
收藏
页码:2976 / 2984
页数:9
相关论文
共 14 条
[1]   Stable isotopes in biosciences, their measurement and models for amino acid metabolism [J].
Bier, DM .
EUROPEAN JOURNAL OF PEDIATRICS, 1997, 156 (Suppl 1) :S2-S8
[2]   INTRINSICALLY DIFFICULT PROBLEMS - THE KINETICS OF BODY PROTEINS AND AMINO-ACIDS IN MAN [J].
BIER, DM .
DIABETES-METABOLISM REVIEWS, 1989, 5 (02) :111-132
[3]   A MASS-SPECTROMETRIC METHOD FOR MEASURING GLYCEROL LEVELS AND ENRICHMENTS IN PLASMA USING C-13 AND H-2 STABLE ISOTOPIC TRACERS [J].
GILKER, CD ;
PESOLA, GR ;
MATTHEWS, DE .
ANALYTICAL BIOCHEMISTRY, 1992, 205 (01) :172-178
[4]   MASS FRAGMENTOGRAPHY - IDENTIFICATION OF CHLORPROMAZINE AND ITS METABOLITIES IN HUMAN BLOOD BY A NEW METHOD [J].
HAMMAR, CG ;
HOLMSTEDT, B ;
RYHAGE, R .
ANALYTICAL BIOCHEMISTRY, 1968, 25 (1-3) :532-+
[5]   Theoretical maximal precision for mass-to-charge ratio, amplitude, and width measurements in ion-counting mass analysers [J].
Lee, HN ;
Marshall, AG .
ANALYTICAL CHEMISTRY, 2000, 72 (10) :2256-2260
[6]   EFFECT OF EPINEPHRINE ON AMINO-ACID AND ENERGY-METABOLISM IN HUMANS [J].
MATTHEWS, DE ;
PESOLA, G ;
CAMPBELL, RG .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (06) :E948-E956
[7]   DETERMINATION OF STABLE ISOTOPIC ENRICHMENT IN INDIVIDUAL PLASMA AMINO-ACIDS BY CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
MATTHEWS, DE ;
BENGALIM, E ;
BIER, DM .
ANALYTICAL CHEMISTRY, 1979, 51 (01) :80-84
[8]   STABLE ISOTOPE METHODS FOR NUTRITIONAL INVESTIGATION [J].
MATTHEWS, DW ;
BIER, DM .
ANNUAL REVIEW OF NUTRITION, 1983, 3 :309-339
[9]   CONCENTRATION-DEPENDENCE OF METHYL PALMITATE ISOTOPE RATIOS BY ELECTRON-IMPACT IONIZATION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
PATTERSON, BW ;
WOLFE, RR .
BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (08) :481-486
[10]  
Peterson D. W., 1978, CONT TOPICS ANAL CLI