Clinical experience with devices for facilitated anastomoses in coronary artery bypass surgery

被引:29
作者
Carrel, TP [1 ]
Eckstein, FS [1 ]
Englberger, L [1 ]
Berdat, PA [1 ]
Schmidli, J [1 ]
机构
[1] Univ Hosp Bern, Cardiovasc Surg Clin, CH-3010 Bern, Switzerland
关键词
D O I
10.1016/j.athoracsur.2003.08.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recent developments in minimally invasive coronary artery surgery have been driven by the introduction of new technologies which should facilitate precise surgical maneuvers on the beating heart within confined spaces. Such technologies include coronary stabilizer systems, cardiac positioning vacuum-assisted devices, and telemanipulative systems. Despite these developments, standard suturing techniques using running polypropylene material remains a limiting factor in the surgeon's ability to perform complete revascularization with high quality anastomoses through minimal approaches to the chest cavity. Clinical validation of proximal and distal anastomotic devices has the potential to substantially improve and perhaps revolutionize minimally invasive coronary surgery. Ideal characteristics of such devices would include applicability to all conduit types, all coronary sizes, interchangeable proximal/distal sequencing of the anastomosis, and safe bail out for device malfunction. However there is an urgent need to define the performance objectives of such systems as well as the general criteria for proper and comparable evaluation and validation of different systems in animal models and subsequently in controlled prospective clinical studies. This review summarizes the most interesting systems available in both experimental and clinical settings. (C) 2004 by The Society of Thoracic Surgeons.
引用
收藏
页码:1110 / 1120
页数:11
相关论文
共 75 条
[1]  
*AM COLL SURG STAT, 1994, AM COLL SURG B, V79, P40
[2]  
ANDROSOV PI, 1956, ARCH SURG-CHICAGO, V73, P902
[3]   Safety and efficacy of off-pump coronary artery bypass grafting [J].
Arom, KV ;
Flavin, TF ;
Emery, RW ;
Kshettry, VR ;
Janey, PA ;
Petersen, RJ .
ANNALS OF THORACIC SURGERY, 2000, 69 (03) :704-710
[4]   On-pump versus off-pump coronary revascularization: Evaluation of renal function [J].
Ascione, R ;
Lloyd, CT ;
Underwood, MJ ;
Gomes, WJ ;
Angelini, CD .
ANNALS OF THORACIC SURGERY, 1999, 68 (02) :493-498
[5]   Off-pump coronary artery bypass grafting: Not a flash in the pan [J].
Ascione, R ;
Caputo, M ;
Angelini, GD .
ANNALS OF THORACIC SURGERY, 2003, 75 (01) :306-313
[6]   A comparison of para-anastomotic compliance profiles after vascular anastomosis: Nonpenetrating clips versus standard sutures [J].
Baguneid, MS ;
Goldner, S ;
Fulford, PE ;
Hamilton, G ;
Walker, MG ;
Seifalian, AM .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (04) :812-820
[7]  
BARZILAI B, 1989, CIRCULATION, V80, P275
[8]   Influence of suture technique and suture material selection on the mechanics of end-to-end and end-to-side anastomoses [J].
Baumgartner, N ;
Dobrin, PB ;
Morasch, M ;
Dong, QS ;
Mrkvicka, R .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (05) :1063-1072
[9]   Facilitated vascular interrupted anastomosis in cardiovascular surgery with a new clip device [J].
Berdat, PA ;
Kipfer, B ;
Immer, FF ;
Pfammatter, JP ;
Carrel, T .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (06) :1256-1258
[10]  
BERDAT PA, 2003, UNPUB HEART SURG FOR