Measuring extraocular muscle volume using dynamic contours

被引:20
作者
Firbank, MJ [1 ]
Harrison, RM
Williams, ED
Coulthard, A
机构
[1] Newcastle Univ, Royal Victoria Infirm, Dept Radiol, Newcastle Upon Tyne NE1 4LP, Tyne & Wear, England
[2] Newcastle Gen Hosp, Dept Reg Med Phys, Newcastle Upon Tyne NE4 6BE, Tyne & Wear, England
[3] Sunderland Royal Hosp, Dept Reg Med Phys, Sunderland SR4 7TP, England
关键词
segmentation; deformable model; thyroid associated ophthalmopathy; extraocular muscles;
D O I
10.1016/S0730-725X(01)00234-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The effect of medical treatment on extraocular muscle enlargement in thyroid associated ophthalmopathy (TAO) may be monitored by measuring the change in volume of the extraocular muscles on serial orbital MRI examinations. In theory. 3D image sets offer the opportunity to minimise errors due to poor repositioning and partial volume effects. This study describes an automated technique for estimating extraocular muscle volumes from 3D datasets. Operator input is minimal and the technique is robust. Verification of the technique on both simulated and real datasets is described. For simulated image sets, both automated segmentation and manual outlining produced estimates of volume which were on average 4% less than 'true' volume. For real patient data, extraocular muscle volumes measured by the automated technique were 1.6% (SD 13%) less than volumes measured by manual outlining. Coefficient of variation for repeat outlining of the same image dataset for the automated technique was 1.0%, compared with 4% for manual outlining. The manual technique took an experienced operator approximately 20 min to perform. compared to 7 min fur the automated technique. The automated method is therefore rapid, reproducible and at least as accurate as other available methods. (C) 2001 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:257 / 265
页数:9
相关论文
共 15 条
[1]  
Char D., 1997, THYROID EYE DIS
[2]   ECHOGRAPHIC MONITORING OF RESPONSE OF EXTRAOCULAR-MUSCLES TO IRRADIATION IN GRAVES OPHTHALMOPATHY [J].
ERICKSON, BA ;
HARRIS, GJ ;
LEWANDOWSKI, MF ;
MURRAY, KJ ;
MASSARO, BM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (03) :651-660
[3]   QUANTITATIVE COMPUTED-TOMOGRAPHY OF GRAVES OPHTHALMOPATHY - EXTRAOCULAR-MUSCLE AND ORBITAL FAT IN DEVELOPMENT OF OPTIC NEUROPATHY [J].
FELDON, SE ;
LEE, CP ;
MURAMATSU, SK ;
WEINER, JM .
ARCHIVES OF OPHTHALMOLOGY, 1985, 103 (02) :213-215
[4]   Partial volume effects in MRI studies of multiple sclerosis [J].
Firbank, MJ ;
Coulthard, A ;
Harrison, RM ;
Williams, ED .
MAGNETIC RESONANCE IMAGING, 1999, 17 (04) :593-601
[5]  
FIRBANK MJ, 2000, IN PRESS BRIT J RADI
[6]   VOLUME MEASUREMENTS OF NORMAL ORBITAL STRUCTURES BY COMPUTED TOMOGRAPHIC ANALYSIS [J].
FORBES, G ;
GEHRING, DG ;
GORMAN, CA ;
BRENNAN, MD ;
JACKSON, IT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (01) :149-154
[7]  
Gonzalez R.C., 2007, DIGITAL IMAGE PROCES, V3rd
[8]   The measurement of change in Graves' ophthalmopathy [J].
Gorman, CA .
THYROID, 1998, 8 (06) :539-543
[9]   RADIOTHERAPY IN THE MANAGEMENT OF THYROID ORBITOPATHY - COMPUTED-TOMOGRAPHY AND CLINICAL OUTCOMES [J].
KAO, SCS ;
KENDLER, DL ;
NUGENT, RA ;
ADLER, JS ;
ROOTMAN, J .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :819-823
[10]   SNAKES - ACTIVE CONTOUR MODELS [J].
KASS, M ;
WITKIN, A ;
TERZOPOULOS, D .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1987, 1 (04) :321-331