Duty cycle improvement for a quadrupole-time-of-flight mass spectrometer and its use for precursor ion scans

被引:61
作者
Chernushevich, IV [1 ]
机构
[1] SCIEX, Concord, ON L4K 4V8, Canada
关键词
time-of-flight mass spectrometry; MS/MS; duty cycle; fragment ion; precursor ion;
D O I
10.1255/ejms.377
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Normally, quadrupole-time-of-flight (QqTOF) instruments benefit from a simultaneous recording of all masses, and their sensitivity is higher than that of a triple quadrupole when a full scan is recorded. This is not the case when only a single type of ion has to be monitored, as in precursor ion scanning or multiple-reaction monitoring (MRM) mode. This is because ion losses in TOF are higher than in a quadrupole, A significant part of these losses is due to the low duty cycle of an orthogonal TOF instrument, typically 5 to 30%, Trapping ions in the collision cell and then gating them out in short bursts synchronized with TOF extraction can restore the duty cycle at the expense of mass range. The mechanism of ion trapping, gating and bunching is studied under various conditions. By varying trapping and gating parameters, different modes of operation are achievable: from a 100% duty cycle restoration for a narrow mass range to < 50% duty cycle for a wider mass range. The former mode is best for a single-fragment precursor ion scan, whereas the latter is better when a full product-ion spectrum needs to be recorded, or when a multiple-fragment precursor ion scan is performed. Several examples of precursor ion scans obtained with peptides and lipids are demonstrated. Sensitivity improvements range from x15 for the immonium fragment ion (m/z 86) to x5 for simultaneous recording of lipid fragments with mit = 184 and 264.
引用
收藏
页码:471 / 479
页数:9
相关论文
共 17 条
  • [1] Quantitative analysis of biological membrane lipids at the low picomole level by nano-electrospray ionization tandem mass spectrometry
    Brugger, B
    Erben, G
    Sandhoff, R
    Wieland, FT
    Lehmann, WD
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (06) : 2339 - 2344
  • [2] CARR SA, 1993, PROTEIN SCI, V2, P183
  • [3] CHERNUSHEVICH IV, 1998, P 46 ASMS C MASS SPE, P43
  • [4] Eckers C, 1997, RAPID COMMUN MASS SP, V11, P1916, DOI 10.1002/(SICI)1097-0231(199711)11:17<1916::AID-RCM96>3.0.CO
  • [5] 2-8
  • [6] Exact mass measurement of product ions for the structural elucidation of drug metabolites with a tandem quadrupole orthogonal-acceleration time-of-flight mass spectrometer
    Hopfgartner, G
    Chernushevich, IV
    Covey, T
    Plomley, JB
    Bonner, R
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (12) : 1305 - 1314
  • [7] SELECTIVE DETECTION OF PHOSPHOPEPTIDES IN COMPLEX-MIXTURES BY ELECTROSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    HUDDLESTON, MJ
    ANNAN, RS
    BEAN, MF
    CARR, SA
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (09) : 710 - 717
  • [8] LOBODA A, 2000, 48 ASMS C MASS SPECT
  • [9] Morris HR, 1996, RAPID COMMUN MASS SP, V10, P889, DOI 10.1002/(SICI)1097-0231(19960610)10:8<889::AID-RCM615>3.0.CO
  • [10] 2-F