SELECTIVE DETECTION OF PHOSPHOPEPTIDES IN COMPLEX-MIXTURES BY ELECTROSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY

被引:225
作者
HUDDLESTON, MJ [1 ]
ANNAN, RS [1 ]
BEAN, MF [1 ]
CARR, SA [1 ]
机构
[1] SMITHKLINE BEECHAM PHARMACEUT, DEPT PHYS & STRUCT CHEM, BOX 1539, KING OF PRUSSIA, PA 19406 USA
关键词
D O I
10.1016/1044-0305(93)80049-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A mass spectrometry-based method that does not involve the use of radiolabeling was developed for selective detection of phosphopeptides in complex mixtures. Mixtures of phosphorylated and nonphosphorylated peptides at the low picomole level are analyzed by negative ion electrospray liquid chromatography/mass spectrometry using C-18 packed fused-silica columns (less-than-or-equal-to 320-mum i.d.). Peptides and phosphopeptides in the chromatographic eluant undergo collision-induced dissociation in the free-jet expansion region prior to the mass analyzing quadrupole. Using relatively high collisional excitation potentials, phosphopeptides containing phosphoserine, phosphothreonine, and phosphotyrosine fragment to yield diagnostic ions at m/z 63 and 79 corresponding to PO2- and PO3-, respectively. Chromatographic peaks containing phosphopeptides are indicated where these diagnostic ions maximize. The highest sensitivity for phosphopeptide detection is obtained using selected-ion monitoring for m/z 63 and 79. Full-scan mass spectra that exhibit the diagnostic phosphopeptide fragment ions, together with pseudomolecular ions, may be obtained by stepping the collisional excitation potential from a high value during the portion of each scan in which the low-mass-to-charge ratio diagnostic marker ions are being detected to a lower value while the upper mass-to-charge ratio range is being scanned. Good sensitivity for phosphopeptide detection was achieved using standard trifluoroacetic acid containing mobile phases for reversed-phase high-performance liquid chromatography. Data illustrating the selectivity and sensitivity of the approach are presented for mixtures of peptides and phosphopeptides containing the three commonly phosphorylated amino acids.
引用
收藏
页码:710 / 717
页数:8
相关论文
共 26 条
[1]   CHARACTERIZATION OF POSTTRANSLATIONAL MODIFICATIONS IN NEURON-SPECIFIC CLASS-III BETA-TUBULIN BY MASS-SPECTROMETRY [J].
ALEXANDER, JE ;
HUNT, DF ;
LEE, MK ;
SHABANOWITZ, J ;
MICHEL, H ;
BERLIN, SC ;
MACDONALD, TL ;
SUNDBERG, RJ ;
REBHUN, LI ;
FRANKFURTER, A .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1991, 88 (11) :4685-4689
[2]  
BOYLE WJ, 1991, METHOD ENZYMOL, V201, P110
[3]  
CARR SA, 1993, PROTEIN SCI, V2, P183
[4]   SIGNAL INTEGRATION AT THE LEVEL OF PROTEIN-KINASES, PROTEIN PHOSPHATASES AND THEIR SUBSTRATES [J].
COHEN, P .
TRENDS IN BIOCHEMICAL SCIENCES, 1992, 17 (10) :408-413
[5]  
COHEN P, 1991, METHOD ENZYMOL, V201, P153
[6]  
COVEY T, 1991, ADV LIF SCI, P249
[7]  
ERICKSON AK, 1990, J BIOL CHEM, V265, P19728
[8]   PHOSPHORYLATION SITES IN RIBOFLAVIN-BINDING PROTEIN CHARACTERIZED BY FAST ATOM BOMBARDMENT MASS-SPECTROMETRY [J].
FENSELAU, C ;
HELLER, DN ;
MILLER, MS ;
WHITE, HB .
ANALYTICAL BIOCHEMISTRY, 1985, 150 (02) :309-314
[9]   LIQUID SECONDARY-ION MASS-SPECTROMETRY OF PHOSPHORYLATED AND SULFATED PEPTIDES AND PROTEINS [J].
GIBSON, BW ;
COHEN, P .
METHODS IN ENZYMOLOGY, 1990, 193 :480-501
[10]   ANALYSIS OF PROTEINS AND GLYCOPROTEINS AT THE PICOMOLE LEVEL BY ONLINE COUPLING OF MICROBORE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLOW FAST-ATOM-BOMBARDMENT AND ELECTROSPRAY MASS-SPECTROMETRY - A COMPARATIVE-EVALUATION [J].
HEMLING, ME ;
ROBERTS, GD ;
JOHNSON, W ;
CARR, SA ;
COVEY, TR .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1990, 19 (11) :677-691