Intravascular ultrasound and stent implantation:: Intraobserver and interobserver variability

被引:26
作者
Blessing, E [1 ]
Hausmann, D [1 ]
Sturm, M [1 ]
Wolpers, HG [1 ]
Amende, I [1 ]
Mügge, A [1 ]
机构
[1] Hannover Med Sch, Dept Internal Med, Div Cardiol, D-3000 Hannover, Germany
关键词
D O I
10.1053/hj.1999.v137.93032
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Intravascular ultrasound (IVUS) imaging can be used to optimize implantation of intracoronary stents; the variability of the measurements, however, remains unclear. Our aim in this study was to determine the intraobserver and interobserver variability of IVUS measurements after stent implantation. Methods Ninety-four patients underwent implantation of 100 Palmaz-Schatz stents in 98 lesions (79 de novo and 19 restenotic). IVUS measurements (3.5F, 30 MHz) of proximal and distal reference sections and of the smallest stent lumen were performed by 2 investigators. Results Intraobserver and interobserver correlations, respectively, were r = 0.96 and 0.93 for the proximal reference, r = 0.94 and 0.92 for the distal reference, and r = 0.97 and 0.97 for minimal stent lumen. Stent expansion (minimal lumen in the stent/mean reference area) showed a variability of r = 0.80 and 0.70. Taking a cutoff point of 90% for adequacy of stent expansion,;observers agreed in only 77% whether the stent was adequately or inadequately expanded. Conclusions IVUS enables reproducible lumen measurements in stents and reference sections. The degree of stent expansion, however, underlies a high measurement variability that can lead to different therapeutic strategies.
引用
收藏
页码:368 / 371
页数:4
相关论文
共 20 条
[11]  
Mudra H., 1997, Journal of the American College of Cardiology, V29, p171A
[12]   INTRAVASCULAR ULTRASOUND IMAGING - INVITRO VALIDATION AND PATHOLOGICAL CORRELATION [J].
NISHIMURA, RA ;
EDWARDS, WD ;
WARNES, CA ;
REEDER, GS ;
HOLMES, DR ;
TAJIK, AJ ;
YOCK, PG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) :145-154
[13]   RESTENOSIS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - PATHOLOGICAL OBSERVATIONS IN 20 PATIENTS [J].
NOBUYOSHI, M ;
KIMURA, T ;
OHISHI, H ;
HORIUCHI, H ;
NOSAKA, H ;
HAMASAKI, N ;
YOKOI, H ;
KIM, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (02) :433-439
[14]  
NOKAMURA S, 1994, CIRCULATION, V89, P2026
[15]   ULTRASOUND ANGIOSCOPY - REAL-TIME, TWO-DIMENSIONAL, INTRALUMINAL ULTRASOUND IMAGING OF BLOOD-VESSELS [J].
PANDIAN, NG ;
KREIS, A ;
BROCKWAY, B ;
ISNER, JM ;
SACHAROFF, A ;
BOLEZA, E ;
CARO, R ;
MULLER, D .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (07) :493-494
[16]   CORONARY-ARTERY IMAGING WITH INTRAVASCULAR HIGH-FREQUENCY ULTRASOUND [J].
POTKIN, BN ;
BARTORELLI, AL ;
GESSERT, JM ;
NEVILLE, RF ;
ALMAGOR, Y ;
ROBERTS, WC ;
LEON, MB .
CIRCULATION, 1990, 81 (05) :1575-1585
[17]   RESTENOSIS AFTER BALLOON ANGIOPLASTY - A PRACTICAL PROLIFERATIVE MODEL IN PORCINE CORONARY-ARTERIES [J].
SCHWARTZ, RS ;
MURPHY, JG ;
EDWARDS, WD ;
CAMRUD, AR ;
VLIETSTRA, RE ;
HOLMES, DR .
CIRCULATION, 1990, 82 (06) :2190-2200
[18]   A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
SERRUYS, PW ;
DEJAEGERE, P ;
KIEMENEIJ, F ;
MACAYA, C ;
RUTSCH, W ;
HEYNDRICKX, G ;
EMANUELSSON, H ;
MARCO, J ;
LEGRAND, V ;
MATERNE, P ;
BELARDI, J ;
SIGWART, U ;
COLOMBO, A ;
GOY, JJ ;
VANDENHEUVEL, P ;
DELCAN, J ;
MOREL, MA .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :489-495
[19]   INTRAVASCULAR ULTRASOUND CROSS-SECTIONAL ARTERIAL IMAGING BEFORE AND AFTER BALLOON ANGIOPLASTY INVITRO [J].
TOBIS, JM ;
MALLERY, JA ;
GESSERT, J ;
GRIFFITH, J ;
MAHON, D ;
BESSEN, M ;
MORIUCHI, M ;
MCLEAY, L ;
MCRAE, M ;
HENRY, WL .
CIRCULATION, 1989, 80 (04) :873-882
[20]   A comparison of coronary-artery stenting with angioplasty for isolated stenosis of the proximal left anterior descending coronary artery [J].
Versaci, F ;
Gaspardone, A ;
Tomai, F ;
Crea, F ;
Chiariello, L ;
Gioffre, PA .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (12) :817-822