Thermal conductivity measurement of submicron-thick films deposited on substrates by modified ac calorimetry (laser-heating Angstrom method)

被引:70
作者
Kato, R [1 ]
Maesono, A [1 ]
Tye, RP [1 ]
机构
[1] Ulvac Sinku Riko Inc, Res & Dev, Midori Ku, Yokohama, Kanagawa 226, Japan
关键词
ac calorimetry; aluminum nitride; aluminum oxide; Angstrom method; CD-R; thermal conductivity; thermal diffusivity; thin film;
D O I
10.1023/A:1010745603645
中图分类号
O414.1 [热力学];
学科分类号
摘要
Technological development, especially in microelectronics. necessitates the development of new and improved methods for measuring the thermal properties of materials, especially in the form of ultrathin films. Previously, modified ac calorimetry (laser-heating Angstrom method) using a scanning laser as the energy source was developed and shown to provide accurate values of thermal diffusivity and derived thermal conductivity for a broad range of materials in the form of free-standing thin sheets or films, wires including fiber bundles, and some films on substrates. This payer describes further applications of the modified ac-calorimetry technique for measurements of the thermal conductivity of thin films deposited on substrates. It was used to measure successfully the thermal conductivities of 1000- to 3000-A-thick aluminum nitride films, aluminum oxide films, etc., which were deposited on a glass substrate. It was also shown to be suitable for developmental measurements on submicron-thick chromatic films deposited on a PET substrate, which are photothermal recording layers, used in the media of CD-R drives of computer systems.
引用
收藏
页码:617 / 629
页数:13
相关论文
共 19 条
[1]  
Angstrom A.J., 1861, ANN PHYS, V114, P513
[2]   HEAT-FLOW AND LATTICE-VIBRATIONS IN GLASSES [J].
CAHILL, DG ;
POHL, RO .
SOLID STATE COMMUNICATIONS, 1989, 70 (10) :927-930
[3]  
Einstein A, 1911, ANN PHYS-BERLIN, V35, P679
[4]  
FUJII K, 1998, P 19 JPN S THERM PRO, P220
[5]   Report on a second round robin measurement of the thermal conductivity of CVD diamond [J].
Graebner, JE ;
Altmann, H ;
Balzaretti, NM ;
Campbell, R ;
Chae, HB ;
Degiovanni, A ;
Enck, R ;
Feldman, A ;
Fournier, D ;
Fricke, J ;
Goela, JS ;
Gray, KJ ;
Gu, YQ ;
Hatta, I ;
Hartnett, TM ;
Imhof, RE ;
Kato, R ;
Koidl, P ;
Kuo, PK ;
Lee, TK ;
Maillet, D ;
Remy, B ;
Roger, JP ;
Seong, DJ ;
Tye, RP ;
Verhoeven, H ;
Wörner, E ;
Yehoda, JE ;
Zachai, R ;
Zhang, B .
DIAMOND AND RELATED MATERIALS, 1998, 7 (11-12) :1589-1604
[6]   DEVELOPMENT OF AC CALORIMETRIC METHOD FOR THERMAL-DIFFUSIVITY MEASUREMENT .4. FILMS WITH LOW THERMAL-DIFFUSIVITY AND VERY THIN-FILMS [J].
GU, YQ ;
HATTA, I .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1991, 30 (06) :1295-1298
[7]   INGENIOUS METHOD FOR ELIMINATING EFFECTS OF HEAT-LOSS IN MEASUREMENTS OF THERMAL-DIFFUSIVITY BY AC CALORIMETRIC METHOD [J].
GU, YQ ;
TANG, XW ;
XU, Y ;
HATTA, I .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 1993, 32 (9B) :L1365-L1367
[8]   DEVELOPMENT OF AC CALORIMETRIC METHOD FOR THERMAL-DIFFUSIVITY MEASUREMENT .1. CONTRIBUTION OF THERMOCOUPLE ATTACHMENT IN A THIN SAMPLE [J].
HATTA, I ;
KATO, R ;
MAESONO, A .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1986, 25 (06) :L493-L495
[9]   THERMAL-DIFFUSIVITY MEASUREMENT OF THIN-FILMS BY MEANS OF AN AC CALORIMETRIC METHOD [J].
HATTA, I ;
SASUGA, Y ;
KATO, R ;
MAESONO, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (08) :1643-1647
[10]   DEVELOPMENT OF AC CALORIMETRIC METHOD FOR THERMAL-DIFFUSIVITY MEASUREMENT .2. SAMPLE DIMENSION REQUIRED FOR THE MEASUREMENT [J].
HATTA, I ;
KATO, R ;
MAESONO, A .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1987, 26 (03) :475-478