Intravascular MR-monitored balloon angioplasty: An in vivo feasibility study

被引:48
作者
Yang, XM
Bolster, BD
Kraitchman, DL
Atalar, E
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Sch Med, Dept Biomed Engn, Baltimore, MD 21287 USA
[3] Kuopio Univ Hosp, Depr Clin Radiol, SF-70210 Kuopio, Finland
[4] Bilkent Univ, Dept Elect Engn, Ankara, Turkey
关键词
angioplasty; experimental; magnetic resonance (MR); intravascular;
D O I
10.1016/S1051-0443(98)70429-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To develop a new method for monitoring balloon angioplasty by using an intravascular magnetic resonance (MR) imaging technique. MATERIALS AND METHODS: Nine New Zealand White rabbits were used: seven for technique refinement, including surgery, device insertion, stenosis creation, and MR protocol development; and two for the final MR imaging of the balloon angioplasty, The in vivo experimental method involved insertion of a catheter antenna and a balloon catheter, via femoral arteriotomies bilaterally, into the target site of the upper abdominal aorta, where a stenosis was artificially created by binding a plastic cable tie. Then, the entire process of the dilation of the stenosis with balloon inflation was monitored under MR fluoroscopy. RESULTS: Catheter insertions were successful, and a 5-mm-long stenosis of the aorta was produced in all nine rabbits, Eight complete balloon angioplasty procedures were satisfactorily monitored and recorded, showing clearly the stenosis of the aorta at the beginning of the procedure, the dilation of the stenosis during the balloon inflation, and the complete opening of the stenosis after balloon dilation, CONCLUSION: Preliminary results of in vivo balloon angioplasty monitored with intravascular MR imaging are presented, MR fluoroscopy, based on the intravascular MR imaging technique, may represent a potential alternative to x-ray fluoroscopy for guiding interventional treatment of cardiovascular diseases.
引用
收藏
页码:953 / 959
页数:7
相关论文
共 33 条
[1]   High resolution intravascular MRI and MRS by using a catheter receiver coil [J].
Atalar, E ;
Bottomley, PA ;
Ocali, O ;
Correia, LCL ;
Kelemen, MD ;
Lima, JAC ;
Zerhouni, EA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :596-605
[2]  
ATALAR E, 1998, IN PRESS MAGN RESON
[3]   OXYGENATION IN THE RABBIT MYOCARDIUM - ASSESSMENT WITH SUSCEPTIBILITY-DEPENDENT MR-IMAGING [J].
ATALAY, MK ;
FORDER, JR ;
CHACKO, VP ;
KAWAMOTO, S ;
ZERHOUNI, EA .
RADIOLOGY, 1993, 189 (03) :759-764
[4]   MR IMAGING OF MOTION WITH SPATIAL MODULATION OF MAGNETIZATION [J].
AXEL, L ;
DOUGHERTY, L .
RADIOLOGY, 1989, 171 (03) :841-845
[5]   MR-guided endovascular interventions: Susceptibility-based catheter and near-real-time imaging technique [J].
Bakker, CJ ;
Hoogeveen, RM ;
Hurtak, WF ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WPTM .
RADIOLOGY, 1997, 202 (01) :273-276
[6]  
Beebe HG, 1997, J ENDOVASC SURG, V4, P111, DOI 10.1583/1074-6218(1997)004<0111:IMFAE>2.0.CO
[7]  
2
[8]   Intravascular magnetic resonance imaging of aortic atherosclerotic plaque composition [J].
Correia, LCL ;
Atalar, E ;
Kelemen, MD ;
Ocali, O ;
Hutchins, GM ;
Fleg, JL ;
Gerstenblith, G ;
Zerhouni, EA ;
Lima, JAC .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1997, 17 (12) :3626-3632
[9]   MR angiography of patients with peripheral arterial disease before and after transluminal angioplasty [J].
Davis, CP ;
Schopke, WD ;
Seifert, B ;
Schneider, E ;
Pfammatter, T ;
Debatin, JF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (04) :1027-1034
[10]  
Duerinckx AJ, 1996, EUR RADIOL, V6, P312