Accuracy of color Doppler velocity in the flow field proximal to a regurgitant orifice: Implications for color Doppler quantitation of valvular incompetence

被引:16
作者
Perry, GJ
Anayiotos, AS
Green, DW
Myers, JG
Fan, PH
Nanda, NC
机构
[1] UNIV ALABAMA,DIV CARDIOVASC DIS,BIRMINGHAM,AL 35294
[2] UNIV ALABAMA,DEPT MECH ENGN,BIRMINGHAM,AL
[3] VET ADM MED CTR,CARDIOL SECT 111H,BIRMINGHAM,AL
关键词
ultrasound echocardiography; color Doppler flow mapping; numerical simulation; hemodynamics; valvular regurgitation; proximal orifice flow field; spatial beam characteristics; error analysis;
D O I
10.1016/0301-5629(96)00029-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Color Doppler is routinely used in estimates of valvular regurgitation. Velocity and subsequently flow measurements are made at about 7-10 cm from the ultrasonic transducer. Error in velocity measurement may occur due to spatial broadening of the color Doppler beam in the axial, azimuthal and lateral directions. Error in velocity may also occur due to wall filters since the filtering process is not uniform throughout the velocity range indicated by the color bar. An attempt to estimate this error was made using an in vitro orifice model, a numerical finite element model (FEM), and information from the manufacturer. We found that the acoustic beam spatial expansion, wall filter sensitivity and Nyquist limit (NYL) have to be considered simultaneously to account for errors. The combined spatial expansion and wall filter effect on velocity was estimated as a weighted average over the sample volume. The error distributions are not universal but depend on orifice size and flow. For a 3-mm orifice and 100 cm s NYL the overall effect was overestimation of low velocities and significant underestimation of high velocities due to the high velocity gradients inside the sample volume. For the 5- and the 10-mm orifice the effect was less accentuated. Based on this overall error distribution, a correction was incorporated on color Doppler obtained data. The incorporated correction yielded better agreement with numerical velocity data. This correction is important in the application of the proximal isovelocity surface area (PISA) technique and the evaluation of regurgitant flowrates.
引用
收藏
页码:605 / 621
页数:17
相关论文
共 20 条
  • [1] A NUMERICAL AND EXPERIMENTAL INVESTIGATION OF THE FLOW ACCELERATION REGION PROXIMAL TO AN ORIFICE
    ANAYIOTOS, AS
    PERRY, GJ
    MYERS, JG
    GREEN, DW
    FAN, PH
    NANDA, NC
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (04) : 501 - 516
  • [2] A NEW METHOD FOR QUANTITATION OF MITRAL REGURGITATION BASED ON COLOR FLOW DOPPLER IMAGING OF FLOW CONVERGENCE PROXIMAL TO REGURGITANT ORIFICE
    BARGIGGIA, GS
    TRONCONI, L
    SAHN, DJ
    RECUSANI, F
    RAISARO, A
    DESERVI, S
    VALDESCRUZ, LM
    MONTEMARTINI, C
    [J]. CIRCULATION, 1991, 84 (04) : 1481 - 1489
  • [3] COMPUTER-ANALYSIS OF DOPPLER COLOR FLOW MAPPING IMAGES FOR QUANTITATIVE ASSESSMENT OF INVITRO FLUID JETS
    BOLGER, AF
    EIGLER, NL
    PFAFF, JM
    RESSER, KJ
    MAURER, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (02) : 450 - 457
  • [4] CAPE EG, 1988, J AM COLL CARDIOL, V12, P1354
  • [5] CHEN C, 1991, CIRCULATION S2, V84, P637
  • [6] COLOR DOPPLER DETERMINATION OF REGURGITANT FLOW - FROM PROXIMAL ISOVELOCITY SURFACE-AREAS TO PROXIMAL VELOCITY PROFILES - AN INVITRO STUDY
    GIESLER, MO
    STAUCH, M
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1992, 9 (01): : 51 - 62
  • [7] COLOR DOPPLER ASSESSMENT OF MITRAL REGURGITATION WITH ORTHOGONAL PLANES
    HELMCKE, F
    NANDA, NC
    HSIUNG, MC
    SOTO, B
    ADEY, CK
    GOYAL, RG
    GATEWOOD, RP
    [J]. CIRCULATION, 1987, 75 (01) : 175 - 183
  • [8] MYERS JG, 1993, ADV BIOENG, V23, P559
  • [9] PERRY G J, 1990, Cardiology Clinics, V8, P265
  • [10] EVALUATION OF AORTIC-INSUFFICIENCY BY DOPPLER COLOR FLOW MAPPING
    PERRY, GJ
    HELMCKE, F
    NANDA, NC
    BYARD, C
    SOTO, B
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (04) : 952 - 959