Elimination of Sampling-Induced Dead Bands in Multiple-Sampled Pulse Width Modulators for DC-DC Converters

被引:2
作者
Corradini, L. [1 ]
Mattavelli, P. [2 ]
Saggini, S. [3 ]
机构
[1] Univ Padua, DEI, I-35100 Padua, Italy
[2] Univ Padua, DTG, I-35100 Padua, Italy
[3] Univ Padua, DIEGM, I-35100 Padua, Italy
来源
IECON 2007: 33RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, CONFERENCE PROCEEDINGS | 2007年
关键词
D O I
10.1109/IECON.2007.4460373
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In multiple-sampled pulse width modulators (MSPWM) the sampling frequency of the modulating, signal is higher than the switching frequency of the power converter. MSPWMs have been shown to exhibit a drastically lower phase lag with respect to their single-sampled counterparts, thus allowing for higher closed-loop bandwidths to be achieved. However the increased sampling frequency gives rise to nonlinear phenomena called sampling-induced dead hands that negatively affect the system operation, as they introduce zero-differential gain regions in the modulator transcharacteristics. This paper proposes a correction algorithm that allows for dead-band removal, thus making the PWM gain constant with respect to the imposed modulating signal. This result is achieved by a simple solution that can be easily implemented without specific hardware requirements. Simulation and experimental results on a dc-dc synchronous buck converter are provided to show the effectiveness and overall simplicity of the proposed solution.
引用
收藏
页码:1495 / +
页数:2
相关论文
共 12 条
[1]  
CORRADINI L, 2006, 37 POW EL SPEC C PES
[2]  
CORRADINI L, 38 IEEE POW EL SPEC
[3]  
MAKSIMOVIC D, IEEE COMPEL 06 0716
[4]  
MAKSIMOVIC D, 2004 P 16 INT S POW, P13
[5]  
MIDDLEBROOK RD, ADV SWITCHED MODE PO, V1
[6]   High-frequency digital PWM controller IC for DC-DC converters [J].
Patella, BJ ;
Prodic, A ;
Zirger, A ;
Maksimovic, D .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2003, 18 (01) :438-446
[7]  
PENG H, 2004, 35 ANN IEEE POW EL S, V6, P4312
[8]  
Prodic A, 2002, ANN WORKSH COMP POW, P18, DOI 10.1109/CIPE.2002.1196709
[9]   Digital pulse width modulator architectures [J].
Syed, A ;
Ahmed, E ;
Maksimovic, D ;
Alarcón, E .
PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, :4689-4695
[10]  
Tedeschi E, 2006, IEEE IND ELEC, P5190