Characterisation of partial volume effect and region-based correction in small animal positron emission tomography (PET) of the rat brain

被引:41
作者
Lehnert, Wencke [1 ,2 ]
Gregoire, Marie-Claude [3 ]
Reilhac, Anthonin [3 ]
Meikle, Steven R. [1 ,2 ]
机构
[1] Univ Sydney, Ramaciotti Imaging Ctr, Brain & Mind Res Inst, Camperdown, NSW 2050, Australia
[2] Univ Sydney, Fac Hlth Sci, Discipline Med Radiat Sci, Lidcombe, NSW 1825, Australia
[3] Australian Nucl Sci & Technol Org, Lucas Heights, NSW 2234, Australia
基金
澳大利亚研究理事会;
关键词
Positron emission tomography (PET); Rat brain imaging; Quantification; Partial volume effect; Partial volume correction; MONTE-CARLO; MICROPET R4; PERFORMANCE EVALUATION; SYSTEM; BINDING; DESIGN; RANGE; MODEL; C-11-RACLOPRIDE; IMPLEMENTATION;
D O I
10.1016/j.neuroimage.2012.02.032
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Accurate quantification of PET imaging data is required for a useful interpretation of the measured radioactive tracer concentrations. The partial volume effect (PVE) describes signal dilution and mixing due to spatial resolution and sampling limitations, which introduces bias in quantitative results. In the present study we investigated the magnitude of PVE for volumes of interest (VOIs) in the rat brain and the effect of positron range. In simulated C-11-raclopride studies we examined the influence of PVE on time activity curves in striatal and cerebellar VOIs and binding potential estimation. The performance of partial volume correction (PVC) was studied using the region-based geometric transfer matrix (GTM) method including the question of whether a spatially variant point spread function (PSF) is necessary for PVC of a rat brain close to the centre of the field of view. Furthermore, we determined the effect of spillover from activity outside the brain. The results confirmed that PVE is significant in rat brain PET and showed that positron range is an important factor that needs to be included in the PSF. There was considerable bias in time activity curves for the simulated C-11-raclopride studies and significant underestimation of binding potential even for very small centred VOIs. Good activity recovery was achieved with the GTM PVC using a spatially invariant simulated PSF when no activity was present outside the brain. PVC using a simple Gaussian fit point spread function was not sufficiently accurate. Spillover from regions outside the brain had a significant impact on measured activity concentrations and reduced the accuracy of PVC with the GTM method using rat brain regions alone, except for the smallest VOI size but at the cost of increased noise. Voxel-based partial volume correction methods which inherently compensate for spillover from outside the brain might be a more suitable choice. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:2144 / 2157
页数:14
相关论文
共 57 条
[1]   Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction [J].
Alessio, Adam M. ;
Stearns, Charles W. ;
Tong, Shan ;
Ross, Steven G. ;
Kohlmyer, Steve ;
Ganin, Alex ;
Kinahan, Paul E. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (03) :938-949
[2]  
Alexoff DL, 2003, J NUCL MED, V44, P815
[3]   Positron emission tomography partial volume correction: Estimation and algorithms [J].
Aston, JAD ;
Cunningham, VJ ;
Asselin, MC ;
Hammers, A ;
Evans, AC ;
Gunn, RN .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2002, 22 (08) :1019-1034
[4]   Performance Evaluation of the Inveon Dedicated PET Preclinical Tomograph Based on the NEMA NU-4 Standards [J].
Bao, Qinan ;
Newport, Danny ;
Chen, Mu ;
Stout, David B. ;
Chatziioannou, Arion F. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (03) :401-408
[5]   QUANTITATION OF THE HUMAN BASAL GANGLIA WITH POSITRON EMISSION TOMOGRAPHY - A PHANTOM STUDY OF THE EFFECT OF CONTRAST AND AXIAL POSITIONING [J].
BENDRIEM, B ;
DEWEY, SL ;
SCHLYER, DJ ;
WOLF, AP ;
VOLKOW, ND .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (02) :216-222
[6]   FILTERING CAPABILITIES AND CONVERGENCE OF THE VAN-CITTERT DECONVOLUTION TECHNIQUE [J].
BENNIA, A ;
RIAD, SM .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1992, 41 (02) :246-250
[7]   THE DESIGN AND PHYSICAL CHARACTERISTICS OF A SMALL ANIMAL POSITRON EMISSION TOMOGRAPH [J].
BLOOMFIELD, PM ;
RAJESWARAN, S ;
SPINKS, TJ ;
HUME, SP ;
MYERS, R ;
ASHWORTH, S ;
CLIFFORD, KM ;
JONES, WF ;
BYARS, LG ;
YOUNG, J ;
ANDREACO, M ;
WILLIAMS, CW ;
LAMMERTSMA, AA ;
JONES, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (06) :1105-1126
[8]  
Casteels C, 2006, J NUCL MED, V47, P1858
[9]   Molecular imaging of small animals with dedicated PET tomographs [J].
Chatziioannou, AF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2002, 29 (01) :98-114
[10]   A rat head holder for simultaneous scanning of two rats in small animal PET scanners: Design, construction, feasibility testing and kinetic validation [J].
Cheng, Tee Ean ;
Yoder, Karmen K. ;
Normandin, Marc D. ;
Risacher, Shannon L. ;
Converse, Alexander K. ;
Hampel, Joseph A. ;
Miller, Michael A. ;
Morris, Evan D. .
JOURNAL OF NEUROSCIENCE METHODS, 2009, 176 (01) :24-33