Determination of γ-hydroxybutyric acid in biological fluids by using capillary electrophoresis with indirect detection

被引:31
作者
Bortolotti, F [1 ]
De Paoli, G [1 ]
Gottardo, R [1 ]
Trattene, M [1 ]
Tagliaro, F [1 ]
机构
[1] Univ Verona, Unit Forens Med, Dept Med & Publ Hlth, Policlin GB Rossi, I-37134 Verona, Italy
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2004年 / 800卷 / 1-2期
关键词
direct injection; gamma-hydroxybutyric acid;
D O I
10.1016/j.jchromb.2003.09.062
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
g-Hydroxybutyric acid (GHB) is a central nervous system (CNS) depressant and hypnotic which, in recent times, has shown an increasing abuse either as recreational drug (due to its euphoric effects and ability to reduce inhibitions) or as doping agent (enhancer of muscle growth). Analogues of GHB, namely gamma-butyrolactone (GBL) and 1,4-butanediol (1,4-BD), share its biological activity and are rapidly converted in vivo into GHB. At present, GHB and analogues are placed in the Schedules of Controlled Substances. Numerous intoxications in GHB abusers have been reported with depressive effects, seizures, coma and possibly death. The purpose of the present work was the development of a rapid analytical method based on capillary zone electrophoresis for the direct determination of GHB in human urine and serum at potentially toxic concentrations. Analytical conditions were as follows. Capillary: length 40 cm (to detector), 75 mum i.d.; buffer: 5.0 mM Na2HPO4, 15 MM sodium barbital adjusted to pH 12 with 1.0 M NaOH; voltage: 25 kV at 23 degreesC; indirect UV detection at 214 nm; injection by application of 0.5 psi for 5 s. alpha-Hydroxyisobutyric acid was used as internal standard (IS). Sample pretreatment was limited to 1:8 dilution. Under these conditions, the sensitivity was similar to3.0 mug/ml (signal-to-noise ratio >3). Calibration curves prepared in water, urine and serum were linear over concentration ranges 25-500 mug/ml with R-2 greater than or equal to 0.998. Analytical precision was fairly good with R.S.D. < 0.60% (including intraday and day-to-day tests). Quantitative precision in both intraday and day-to-day experiments was also very satisfactory with R.S.D. < 4.0%. No interferences were found neither from the most common "drugs of abuse" nor from endogenous compounds. In conclusion, capillary electrophoresis can offer a rapid, precise and accurate method for GHB determination of biological fluids, which could be important for screening purposes in clinical and forensic toxicology. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:239 / 244
页数:6
相关论文
共 18 条
[1]   Determination of γ-hydroxybutyric acid in human urine by capillary electrophoresis with indirect UV detection and confirmation with electrospray ionization ion-trap mass spectrometry [J].
Baldacci, A ;
Theurillat, R ;
Caslavska, J ;
Pardubská, H ;
Brenneisen, R ;
Thormann, W .
JOURNAL OF CHROMATOGRAPHY A, 2003, 990 (1-2) :99-110
[2]  
Blair S, 2001, J FORENSIC SCI, V46, P688
[3]  
Couper F J, 2002, Forensic Sci Rev, V14, P101
[4]   Determination of γ-hydroxybutyrate (GHB) in biological specimens by cas chromatography -: Mass spectrometry [J].
Couper, FJ ;
Logan, BK .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2000, 24 (01) :1-7
[5]   Simultaneous analysis of γ-hydroxybutyric acid, γ-butyrolactone, and 1,4-butanediol by micellar electrokinetic chromatography [J].
Dahlén, J ;
Vriesman, T .
FORENSIC SCIENCE INTERNATIONAL, 2002, 125 (2-3) :113-119
[6]   Development and validation of a high-performance liquid chromatographic method for the determination of γ-hydroxybutyric acid in rat plasma [J].
de Vriendt, CA ;
van Sassenbroeck, DK ;
Rosseel, MT ;
van de Velde, EJ ;
Verstraete, AG ;
Vander Heyden, Y ;
Belpaire, FM .
JOURNAL OF CHROMATOGRAPHY B, 2001, 752 (01) :85-90
[7]   A novel method for GHB detection in urine and its application in drug-facilitated sexual assaults [J].
Elian, AA .
FORENSIC SCIENCE INTERNATIONAL, 2000, 109 (03) :183-187
[8]   Gamma hydroxybutyric acid (GHB) concentrations in humans and factors affecting endogenous production [J].
Elliott, SP .
FORENSIC SCIENCE INTERNATIONAL, 2003, 133 (1-2) :9-16
[9]   THERAPEUTIC GAMMA-HYDROXYBUTYRIC ACID MONITORING IN PLASMA AND URINE BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
FERRARA, SD ;
TEDESCHI, L ;
FRISON, G ;
CASTAGNA, F ;
GALLIMBERTI, L ;
GIORGETTI, R ;
GESSA, GL ;
PALATINI, P .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (06) :483-487
[10]  
Frison G, 2000, RAPID COMMUN MASS SP, V14, P2401, DOI 10.1002/1097-0231(20001230)14:24<2401::AID-RCM179>3.0.CO