Hemocompatibility of Poly(vinylidene fluoride) Membrane Grafted with Network-Like and Brush-Like Antifouling Layer Controlled via Plasma-Induced Surface PEGylation

被引:109
作者
Chang, Yung [1 ]
Shih, Yu-Ju
Ko, Chao-Yin
Jhong, Jheng-Fong
Liu, Ying-Ling
Wei, Ta-Chin
机构
[1] Chung Yuan Christian Univ, R&D Ctr Membrane Technol, Tao Yuan 320, Taiwan
关键词
POLY(ETHYLENE GLYCOL) METHACRYLATE; TRANSFER RADICAL POLYMERIZATION; SELF-ASSEMBLED MONOLAYERS; BLOOD COMPATIBILITY; PROTEIN ADSORPTION; PLATELET-ADHESION; MOLECULAR SIMULATION; COPOLYMER MEMBRANES; PROCOAGULANT ACTIVITY; DEPOSITED TETRAGLYME;
D O I
10.1021/la1048369
中图分类号
O6 [化学];
学科分类号
070301 [无机化学];
摘要
In this work, the hemocompatibility of PEGylated poly(vinylidene fluoride) (PVDF) microporous membranes with varying grafting coverage and structures via plasma-induced surface PEGylation was studied. Network-like and. brush-like PEGylated layers on PVDF membrane surfaces were achieved by low-pressure and atmospheric plasma treatment. The chemical composition, physical morphology, grafting structure, surface hydrophilicity, and hydration capability of prepared membranes were determined to illustrate the correlations between grafting qualities and hemocompatibility of PEGylated PVDF membranes in contact with human blood. Plasma protein adsorption onto different PEGylated PVDF membranes from single-protein solutions and the complex medium of 100% human plasma were measured by enzyme-linked immunosorbent assay (ELISA) with monoclonal antibodies. Hemocompatibility of the PEGylated membranes was evaluated by the antifouling property of platelet adhesion observed by scanning electron microscopy (SEM) and the anticoagulant activity of the blood coagulant determined by testing plasma-clotting time. The control of grafting structures of PEGylated layers highly regulates the PVDF membrane to resist the adsorption of plasma proteins, the adhesion of platelets, and the coagulation of human plasma. It was found that PVDF membranes grafted with brush-like PEGylated layers presented higher hydration capability with binding water molecules than with network-like PEGylated layers to improve the hemocompatible character of plasma protein and blood platelet resistance in human blood. This work suggests that the hemocompatible nature of grafted PEGylated polymers by controlling grafting structures gives them great potential in the molecular design of antithrombogenic membranes for use in human blood.
引用
收藏
页码:5445 / 5455
页数:11
相关论文
共 35 条
[1]
Chemical modification of poly(vinyl chloride) resin using poly(ethylene glycol) to improve blood compatibility [J].
Balakrishnan, B ;
Kumar, DS ;
Yoshida, Y ;
Jayakrishnan, A .
BIOMATERIALS, 2005, 26 (17) :3495-3502
[2]
Plasma-deposited tetraglyme surfaces greatly reduce total blood protein adsorption, contact activation, platelet adhesion, platelet procoagulant activity, and in vitro thrombus deposition [J].
Cao, Lan ;
Chang, Mark ;
Lee, Chi-Ying ;
Castner, David G. ;
Sukavaneshvar, Sivaprasad ;
Ratner, Buddy D. ;
Horbett, Thomas A. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 81A (04) :827-837
[3]
Biofouling-resistance expanded poly(tetrafluoroethylene) membrane with a hydrogel-like layer of surface-immobilized poly(ethylene glycol) methacrylate for human plasma protein repulsions [J].
Chang, Yung ;
Cheng, Ting-Yun ;
Shih, Yu-Ju ;
Lee, Kueir-Rarn ;
Lai, Juin-Yih .
JOURNAL OF MEMBRANE SCIENCE, 2008, 323 (01) :77-84
[4]
Preparation of poly(vinylidene fluoride) microfiltration membrane with uniform surface-copolymerized poly(ethylene glycol) methacrylate and improvement of blood compatibility [J].
Chang, Yung ;
Shih, Yu-Ju ;
Ruaan, Ruoh-Chyu ;
Higuchi, Akon ;
Chen, Wen-Yih ;
Lai, Juin-Yih .
JOURNAL OF MEMBRANE SCIENCE, 2008, 309 (1-2) :165-174
[5]
A systematic SPR study of human plasma protein adsorption behavior on the controlled surface packing of self-assembled poly(ethylene oxide) triblock copolymer surfaces [J].
Chang, Yung ;
Chu, Wan-Ling ;
Chen, Wen-Yih ;
Zheng, Jie ;
Liu, Lingyun ;
Ruaan, Ruoh-chyu ;
Higuchi, Akon .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2010, 93A (01) :400-408
[6]
Hemocompatible Mixed-Charge Copolymer Brushes of Pseudozwitterionic Surfaces Resistant to Nonspecific Plasma Protein Fouling [J].
Chang, Yung ;
Shu, Shih-Hung ;
Shih, Yu-Ju ;
Chu, Chih-Wei ;
Ruaan, Ruoh-Chyu ;
Chen, Wen-Yih .
LANGMUIR, 2010, 26 (05) :3522-3530
[7]
Surface grafting control of PEGylated poly(vinylidene fluoride) antifouling membrane via surface-initiated radical graft copolymerization [J].
Chang, Yung ;
Ko, Chao-Yin ;
Shih, Yu-Ju ;
Quemener, Damien ;
Deratani, Andre ;
Wei, Ta-Chin ;
Wang, Da-Ming ;
Lai, Juin-Yih .
JOURNAL OF MEMBRANE SCIENCE, 2009, 345 (1-2) :160-169
[8]
Atom transfer radical polymerization directly from poly(vinylidene fluoride): Surface and antifouling properties [J].
Chen, Yiwang ;
Liu, Dongmei ;
Deng, Qilan ;
He, Xiaohui ;
Wang, Xiaofeng .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 2006, 44 (11) :3434-3443
[9]
Controlled grafting from poly(vinylidene fluoride) microfiltration membranes via reverse atom transfer radical polymerization and antifouling properties [J].
Chen, Yiwang ;
Deng, Qian ;
Mao, Jichun ;
Nie, Huarong ;
Wu, Lichuan ;
Zhou, Weihua ;
Huang, Biwu .
POLYMER, 2007, 48 (26) :7604-7613
[10]
Poly(vinylidene fluoride) with grafted poly(ethylene glycol) side chains via the RAFT-mediated process and pore size control of the copolymer membranes [J].
Chen, YW ;
Ying, L ;
Yu, WH ;
Kang, ET ;
Neoh, KG .
MACROMOLECULES, 2003, 36 (25) :9451-9457