Description of the frequency dependence of the amplitude and phase angle of a silicon cantilever tapping on a silicon substrate by the harmonic approximation

被引:30
作者
Bar, G
Brandsch, R
Whangbo, MH
机构
[1] Freiburger Mat Forschungszentrum, D-79104 Freiburg, Germany
[2] N Carolina State Univ, Dept Chem, Raleigh, NC 27695 USA
关键词
amplitude curves; frequency sweep; harmonic approximation; hysteresis; phase curves; tapping mode atomic force microscopy;
D O I
10.1016/S0039-6028(98)00348-3
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The frequency dependence of the amplitude and phase angle of a silicon cantilever tapping on a silicon surface was examined. The amplitude and phase angle curves exhibit hysteresis depending on the driving and set-point amplitudes. The main features of these curves are explained in terms of the harmonic approximation. The frequency shifts determined from the phase curves vary almost linearly as a function of the set-point ratio, in support of the harmonic approximation. The quality factor of a tapping cantilever was estimated from amplitude and phase curves using the harmonic approximation. The quality factor is reduced by the tip-sample interaction, and this reduction is stronger when the interaction is dominated by repulsive forces than by attractive forces. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:L802 / L809
页数:8
相关论文
共 26 条
  • [1] Cantilever dynamics in quasinoncontact force microscopy: Spectroscopic aspects
    Anczykowski, B
    Kruger, D
    Fuchs, H
    [J]. PHYSICAL REVIEW B, 1996, 53 (23): : 15485 - 15488
  • [2] Basic properties of dynamic force spectroscopy with the scanning force microscope in experiment and simulation
    Anczykowski, B
    Kruger, D
    Babcock, KL
    Fuchs, H
    [J]. ULTRAMICROSCOPY, 1996, 66 (3-4) : 251 - 259
  • [3] BABCOCK K, 1995, MATER RES SOC SYMP P, V355, P311
  • [4] BACHELOT R, 1997, PROBE MICROSCOPY, V1, P89
  • [5] Factors affecting the height and phase images in tapping mode atomic force microscopy. Study of phase-separated polymer blends of poly(ethene-co-styrene) and poly(2,6-dimethyl-1,4-phenylene oxide)
    Bar, G
    Thomann, Y
    Brandsch, R
    Cantow, HJ
    Whangbo, MH
    [J]. LANGMUIR, 1997, 13 (14) : 3807 - 3812
  • [6] Intermittent contact: tapping or hammering?
    Behrend, OP
    Oulevey, F
    Gourdon, D
    Dupas, E
    Kulik, AJ
    Gremaud, G
    Burnham, NA
    [J]. APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1998, 66 (Suppl 1): : S219 - S221
  • [7] On the factors affecting the contrast of height and phase images in tapping mode atomic force microscopy
    Brandsch, R
    Bar, G
    Whangbo, MH
    [J]. LANGMUIR, 1997, 13 (24) : 6349 - 6353
  • [8] How does a tip tap?
    Burnham, NA
    Behrend, OP
    Oulevey, F
    Gremaud, G
    Gallo, PJ
    Gourdon, D
    Dupas, E
    Kulik, AJ
    Pollock, HM
    Briggs, GAD
    [J]. NANOTECHNOLOGY, 1997, 8 (02) : 67 - 75
  • [9] Energy dissipation in tapping-mode atomic force microscopy
    Cleveland, JP
    Anczykowski, B
    Schmid, AE
    Elings, VB
    [J]. APPLIED PHYSICS LETTERS, 1998, 72 (20) : 2613 - 2615
  • [10] INTERACTION FORCE DETECTION IN SCANNING PROBE MICROSCOPY - METHODS AND APPLICATIONS
    DURIG, U
    ZUGER, O
    STALDER, A
    [J]. JOURNAL OF APPLIED PHYSICS, 1992, 72 (05) : 1778 - 1798