Comparison of four different Shear Wave Elastography platforms according to abdominal wall thickness in liver fibrosis evaluation: a phantom study

被引:20
作者
Lee, Sang Min [1 ,2 ]
Chang, Won [3 ]
Kang, Hyo-Jin [1 ]
Ahn, Su Joa [1 ]
Lee, Jeong-Hoon [4 ]
Lee, Jeong Min [1 ,5 ,6 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, 101 Daehangno, Seoul 110744, South Korea
[2] Hallym Univ, Dept Radiol, Sacred Heart Hosp, Anyang, South Korea
[3] Seoul Natl Univ, Dept Radiol, Bundang Hosp, Seoul, South Korea
[4] Seoul Natl Univ Hosp, Dept Internal Med, Seoul, South Korea
[5] Seoul Natl Univ, Dept Radiol, Coll Med, Seoul, South Korea
[6] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul, South Korea
关键词
shear wave elastography; liver stiffness measurements; abdominal wall thickness; TRANSIENT ELASTOGRAPHY; ULTRASOUND ELASTOGRAPHY; DIAGNOSTIC PERFORMANCE; SAMPLING VARIABILITY; HEPATIC-FIBROSIS; CLINICAL-USE; QUANTIFICATION; METAANALYSIS; GUIDELINES; ACCURACY;
D O I
10.11152/mu-1737
中图分类号
O42 [声学];
学科分类号
070206 [声学];
摘要
Aims: To compare the applicability, reliability acid stiftbss values of four different shear wave elastography (SWE) platforms and to determine the influence of abdominal wall thickness on those of four SWE platforms evaluating liver fibrosis. Material and methods: We used four different SWE platforms: transient elastography (TE), pSWE (S-shear wave), 2D SWE/SSI (SuperSonic Imagine) and 2D SWE/GE (GE Health care). To identify the effect of abdominal wall thickness, five commercially available liver fibrosis phantoms were covered in 1.3 cm and 2.3 cm thick porcine abdominal walls, respectively. All measurements were performed by three observers. Absolute repeatability of each measurement was evaluated using coefficients of variation (CVs). Applicability rate, CVs and mean stiffness values were compared according to platforms and abdominal wall thickness. Results: Applicability rates were significantly different among the four SWE platforms (p<0.001): 2D SWE/SSI showed the lowest applicability rate (68.9%) compared with the other three platforms (TE, 95,6% pSWE, 93.3%, 2D SWE/GE, 97.8%) due to higher technical failure rates in phantoms with thick wall. Repeatability was significantly different according to the platform and abdominal wall thickness. Stillness values did not significantly differ according to abdominal wall thickness, even though the values were significantly different among four platforms in all phantoms. Conclusions: The applicability, repeatability, and stiffness value were different depending on SWE platforms, Further, the applicability and repeatability would be more affected by abdominal wall thickness. Thus, careful consideration should be given to an appropriate SWE platform, when evaluating liver fibrosis in patients with thick abdominal wall.
引用
收藏
页码:22 / 29
页数:8
相关论文
共 37 条
[1]
[Anonymous], 2015, J HEPATOL, V63, P237, DOI 10.1016/j.jhep.2015.04.006
[2]
Elastography Assessment of Liver Fibrosis: Society of Radiologists in Ultrasound Consensus Conference Statement [J].
Barr, Richard G. ;
Ferraioli, Giovanna ;
Palmeri, Mark L. ;
Goodman, Zachary D. ;
Garcia-Tsao, Guadalupe ;
Rubin, Jonathan ;
Garra, Brian ;
Myers, Robert P. ;
Wilson, Stephanie R. ;
Rubens, Deborah ;
Levine, Deborah .
RADIOLOGY, 2015, 276 (03) :845-861
[3]
Sampling variability of liver fibrosis in chronic hepatitis C [J].
Bedossa, P ;
Dargère, D ;
Paradis, V .
HEPATOLOGY, 2003, 38 (06) :1449-1457
[4]
Supersonic shear imaging: A new technique for soft tissue elasticity mapping [J].
Bercoff, J ;
Tanter, M ;
Fink, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) :396-409
[5]
Update on ultrasound imaging of liver fibrosis [J].
Berzigotti, Annalisa ;
Castera, Laurent .
JOURNAL OF HEPATOLOGY, 2013, 59 (01) :180-182
[6]
Why do I treat my patients with mild hepatitis C? [J].
Calvaruso, Vincenza ;
Craxi, Antonio .
LIVER INTERNATIONAL, 2016, 36 :7-12
[7]
Non-invasive assessment of liver fibrosis with impulse elastography: Comparison of Supersonic Shear Imaging with ARFI and FibroScan [J].
Cassinotto, Christophe ;
Lapuyade, Bruno ;
Mouries, Amaury ;
Hiriart, Jean-Baptiste ;
Vergniol, Julien ;
Gaye, Delphine ;
Castain, Claire ;
Le Bail, Brigitte ;
Chermak, Faiza ;
Foucher, Juliette ;
Laurent, Francois ;
Montaudon, Michel ;
De Ledinghen, Victor .
JOURNAL OF HEPATOLOGY, 2014, 61 (03) :550-557
[8]
Pitfalls of Liver Stiffness Measurement: A 5-Year Prospective Study of 13,369 Examinations [J].
Castera, Laurent ;
Foucher, Juliette ;
Bernard, Pierre-Henri ;
Carvalho, Francoise ;
Allaix, Daniele ;
Merrouche, Wassil ;
Couzigou, Patrice ;
de Ledinghen, Victor .
HEPATOLOGY, 2010, 51 (03) :828-835
[9]
Prospective evaluation of transient elastography for the diagnosis of hepatic fibrosis in Asians: comparison with liver biopsy and aspartate transaminase platelet ratio index [J].
Chang, P. -E. ;
Lui, H. -F. ;
Chau, Y. -P. ;
Lim, K. -H. ;
Yap, W. -M. ;
Tan, C. -K. ;
Chow, W. -C. .
ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2008, 28 (01) :51-61
[10]
Accuracy of elastography point quantification and steatosis influence on assessing liver fibrosis in patients with chronic hepatitis C [J].
Conti, Fabio ;
Serra, Carla ;
Vukotic, Ranka ;
Fiorini, Erica ;
Felicani, Cristina ;
Mazzotta, Elena ;
D'Errico, Antonietta ;
Verucchi, Gabriella ;
Lenzi, Marco ;
Andreone, Pietro .
LIVER INTERNATIONAL, 2017, 37 (02) :187-195