Non-invasive assessment of liver fibrosis with impulse elastography: Comparison of Supersonic Shear Imaging with ARFI and FibroScan

被引:354
作者
Cassinotto, Christophe [1 ,2 ]
Lapuyade, Bruno [1 ]
Mouries, Amaury [1 ]
Hiriart, Jean-Baptiste [3 ]
Vergniol, Julien [3 ]
Gaye, Delphine [1 ]
Castain, Claire [4 ]
Le Bail, Brigitte [2 ,4 ]
Chermak, Faiza [3 ]
Foucher, Juliette [3 ]
Laurent, Francois [5 ,6 ]
Montaudon, Michel [5 ,6 ]
De Ledinghen, Victor [2 ,3 ]
机构
[1] Ctr Hosp Univ Bordeaux, Hop Haut Leveque, Dept Diagnost & Intervent Imaging, F-33604 Pessac, France
[2] Univ Bordeaux, INSERM, U1053, Bordeaux, France
[3] Ctr Hosp Univ Bordeaux, Hop Haut Leveque, Ctr Invest Fibrose Hepat, F-33604 Pessac, France
[4] Ctr Hosp Univ Bordeaux, Hop Pellegrin, Dept Pathol, F-33000 Bordeaux, France
[5] CHU, Hop Haut Leveque, Dept Diagnost & Intervent Imaging, F-33604 Pessac, France
[6] Univ Bordeaux, F-33604 Pessac, France
关键词
Non-invasive diagnosis; Elasticity imaging techniques; Ultrasonography; Transient elastography; Liver disease; Cirrhosis; CHRONIC HEPATITIS-C; TRANSIENT ELASTOGRAPHY; WAVE ELASTOGRAPHY; XL PROBE; STIFFNESS; PREDICT; DIAGNOSIS; CIRRHOSIS; PERFORMANCE; INDEX;
D O I
10.1016/j.jhep.2014.04.044
中图分类号
R57 [消化系及腹部疾病];
学科分类号
100201 [内科学];
摘要
Background & Aims: Non-invasive assessment of liver fibrosis by elastography is a rapidly developing field with frequent technological innovations. The aim of this study was to assess the diagnostic performances of Supersonic Shear Imaging (SSI) for the diagnosis of liver fibrosis in chronic liver disease. Methods: A total of 349 consecutive patients with chronic liver diseases who underwent liver biopsy from November 2011 to October 2013 were prospectively enrolled. For each patient, liver stiffness was assessed by SSI, ARFI, FibroScan (R) (M probe for patients with BMI <30 kg/m(2), and XL probe for patients with BMI >= 30 kg/m(2)), performed within two weeks of liver biopsy. Areas under the receiver operating curves (AUROCs) were performed and compared for each degree of liver fibrosis. Results: SSI, FibroScan (R), and ARFI correlated significantly with histological fibrosis score (r = 0.79, p < 0.00001; r = 0.70, p < 0.00001; r = 0.64, p < 0.00001, respectively). AUROCs of SSI, FibroScan (R), and ARFI were 0.89, 0.86, and 0.84 for the diagnosis of mild fibrosis; 0.88, 0.84, and 0.81 for the diagnosis of significant fibrosis; 0.93, 0.87, and 0.89, for the diagnosis of severe fibrosis; 0.93, 0.90, and 0.90 for the diagnosis of cirrhosis, respectively. SSI had a higher accuracy than FibroScan (R) for the diagnosis of severe fibrosis (>= F3) (p = 0.0016), and a higher accuracy than ARFI for the diagnosis of significant fibrosis (>= F2) (p = 0.0003). No significant difference was observed for the diagnosis of mild fibrosis and cirrhosis. Conclusions: SSI is an efficient method for the assessment of liver fibrosis in chronic liver diseases, comparing favourably to FibroScan (R) and ARFI. (C) 2014 European Association for the Study of the Liver. Published by Elsevier B. V. All rights reserved.
引用
收藏
页码:550 / 557
页数:8
相关论文
共 32 条
[1]
[Anonymous], 2002, Statistical Methods in Diagnostic Medicine
[2]
NONINVASIVE IN VIVO LIVER FIBROSIS EVALUATION USING SUPERSONIC SHEAR IMAGING: A CLINICAL STUDY ON 113 HEPATITIS C VIRUS PATIENTS [J].
Bavu, Eric ;
Gennisson, Jean-Luc ;
Couade, Mathieu ;
Bercoff, Jeremy ;
Mallet, Vincent ;
Fink, Mathias ;
Badel, Anne ;
Vallet-Pichard, Anais ;
Nalpas, Bertrand ;
Tanter, Mickael ;
Pol, Stanislas .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (09) :1361-1373
[3]
Sampling variability of liver fibrosis in chronic hepatitis C [J].
Bedossa, P ;
Dargère, D ;
Paradis, V .
HEPATOLOGY, 2003, 38 (06) :1449-1457
[4]
BEDOSSA P, 1994, HEPATOLOGY, V20, P15
[5]
Supersonic shear imaging: A new technique for soft tissue elasticity mapping [J].
Bercoff, J ;
Tanter, M ;
Fink, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) :396-409
[6]
Meta-analysis: ARFI elastography versus transient elastography for the evaluation of liver fibrosis [J].
Bota, Simona ;
Herkner, Harald ;
Sporea, Ioan ;
Salzl, Petra ;
Sirli, Roxana ;
Neghina, Adriana M. ;
Peck-Radosavljevic, Markus .
LIVER INTERNATIONAL, 2013, 33 (08) :1138-1147
[7]
Determination of reliability criteria for liver stiffness evaluation by transient elastography [J].
Boursier, Jerome ;
Zarski, Jean-Pierre ;
de Ledinghen, Victor ;
Rousselet, Marie-Christine ;
Sturm, Nathalie ;
Lebail, Brigitte ;
Fouchard-Hubert, Isabelle ;
Gallois, Yves ;
Oberti, Frederic ;
Bertrais, Sandrine ;
Cales, Paul .
HEPATOLOGY, 2013, 57 (03) :1182-1191
[8]
Nonalcoholic steatohepatitis: Definition and pathology [J].
Brunt, EM .
SEMINARS IN LIVER DISEASE, 2001, 21 (01) :3-16
[9]
Liver Fibrosis: Noninvasive Assessment with Acoustic Radiation Force Impulse Elastography-Comparison with FibroScan M and XL Probes and FibroTest in Patients with Chronic Liver Disease [J].
Cassinotto, Christophe ;
Lapuyade, Bruno ;
Ait-Ali, Ania ;
Vergniol, Julien ;
Gaye, Delphine ;
Foucher, Juliette ;
Bailacq-Auder, Claire ;
Chermak, Faiza ;
Le Bail, Brigitte ;
de Ledinghen, Victor .
RADIOLOGY, 2013, 269 (01) :283-292
[10]
Prospective comparison of transient elastography, fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C [J].
Castéra, L ;
Vergniol, J ;
Foucher, J ;
Le Bail, B ;
Chanteloup, E ;
Haaser, M ;
Darriet, M ;
Couzigou, P ;
De Lédinghen, V .
GASTROENTEROLOGY, 2005, 128 (02) :343-350