Different conditions that could result in the bispectral index indicating an incorrect hypnotic state

被引:319
作者
Dahaba, AA [1 ]
机构
[1] Graz Med Univ, Dept Anaesthesiol & Intens Care Med, A-8036 Graz, Austria
关键词
D O I
10.1213/01.ane.0000167269.62966.af
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
Since its introduction in 1996, the Bispectral Index (BIS) has gained increasing popularity in daily anesthesia practice. However, numerous reports have been appearing in the literature of paradoxical BIS changes and inaccurate readings. The purpose of this review is to assess the utility of BIS monitoring through examining the various published reports of all BIS values not coinciding with a clinically judged sedative-hypnotic state, whether arising from an underlying pathophysiology of electroencephalographic (EEG) cerebral function or because of shortcomings in the performance and design of the BIS monitor. High electromyographic activity and electric device interference could create subtle artifact signal pollution without their necessarily being displayed as artifacts. This would be misinterpreted by the BIS algorithm as EEG activity and assigned a spuriously increased BIS value. Numerous clinical conditions that have a direct effect on EEG cerebral function could also directly influence the BIS value.
引用
收藏
页码:765 / 773
页数:9
相关论文
共 79 条
[1]
HYPOTHERMIA ELIMINATES ISOFLURANE REQUIREMENTS AT 20-DEGREES-C [J].
ANTOGNINI, JF .
ANESTHESIOLOGY, 1993, 78 (06) :1152-1156
[2]
The use of bispectral index during a cardiopulmonary arrest: a potential predictor of cerebral perfusion [J].
Azim, N ;
Wang, CY .
ANAESTHESIA, 2004, 59 (06) :610-612
[3]
Spurious bispectral index values due to electromyographic activity [J].
Baldesi, O ;
Bruder, N ;
Velly, L ;
Gouin, E .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (04) :324-325
[4]
Nitrous oxide does not alter bispectral index:: study with nitrous oxide as sole agent and as an adjunct to i.v. anaesthesia [J].
Barr, G ;
Jakobsson, JG ;
Öwall, A ;
Anderson, RE .
BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (06) :827-830
[5]
Billard V, 2001, CAN J ANAESTH, V48, P1055, DOI 10.1007/BF03020368
[6]
Bjorgaas M, 1998, DIABETIC MED, V15, P30, DOI 10.1002/(SICI)1096-9136(199801)15:1<30::AID-DIA526>3.3.CO
[7]
2-I
[8]
Bispectral index variations during tracheal suction in mechanically ventilated critically ill patients: effect of an alfentanil bolus [J].
Brocas, E ;
Dupont, H ;
Paugam-Burtz, C ;
Servin, F ;
Mantz, J ;
Desmonts, JM .
INTENSIVE CARE MEDICINE, 2002, 28 (02) :211-213
[9]
Electromyographic activity falsely elevates the bispectral index [J].
Bruhn, J ;
Bouillon, TW ;
Shafer, SL .
ANESTHESIOLOGY, 2000, 92 (05) :1485-1487
[10]
Onset of propofol-induced burst suppression may be correctly detected as deepening of anaesthesia by approximate entropy but not by bispectral index [J].
Bruhn, J ;
Bouillon, TW ;
Shafer, SL .
BRITISH JOURNAL OF ANAESTHESIA, 2001, 87 (03) :505-507