Coupling of full adsorption-desorption and size-exclusion chromatography (FAD-SEC) has been applied to the separation and molecular characterization of three- and four-component polymer blends. The method is based on the full adsorption of all n or n - 1 components of the polymer blend in a specially designed FAD minicolumn. By appropriate eluent switching the adsorbed polymers are desorbed stepwise from the FAD minicolumn into an on-line SEC column for molecular characterization. It is shown that the desorption isotherms of particular blend components give valuable information about the appropriate displacer composition. The exact position of the desorption isotherms depends, however, both on the amount of polymer adsorbed and in the presence of other, chemically different, polymers within FAD column. The nature and composition of the displacer must, therefore, be adjusted if the intervals between the desorption of particular blend components are to be large enough to prevent displacement overlap.
引用
收藏
页码:65 / 70
页数:6
相关论文
共 28 条
[11]  
HUNKELER D, 1993, ACS SYM SER, V521, P90
[12]   LIQUID-CHROMATOGRAPHY OF POLYMER MIXTURES APPLYING A COMBINATION OF EXCLUSION AND FULL ADSORPTION MECHANISMS .2. ELUENT SWITCHING APPROACH [J].
JANCO, M ;
BEREK, D ;
PRUDSKOVA, T .
POLYMER, 1995, 36 (17) :3295-3299
[13]   Liquid chromatography of polymer mixtures applying combination of exclusion and full adsorption/desorption mechanisms .3. Role of adsorption column and adsorbing eluent [J].
Janco, M ;
Prudskova, T ;
Berek, D .
INTERNATIONAL JOURNAL OF POLYMER ANALYSIS AND CHARACTERIZATION, 1997, 3 (04) :319-332
[14]  
JANCO M, 1995, J APPL POLYM SCI, V55, P393
[15]   New aspects of determination of polymer heterogeneity by 2-dimensional orthogonal liquid chromatography and MALDI-TOF-MS [J].
Kruger, RP ;
Much, H ;
Schulz, G ;
Wachsen, O .
MACROMOLECULAR SYMPOSIA, 1996, 110 :155-176
[16]   Polymer molecular weight characterization by temperature gradient high performance liquid chromatography [J].
Lee, HC ;
Chang, TY .
POLYMER, 1996, 37 (25) :5747-5749
[17]   CHARACTERIZATION OF BINARY POLYMER MIXTURES BY SIZE-EXCLUSION CHROMATOGRAPHY WITH MULTIPLE DETECTION [J].
LEE, HC ;
REE, M ;
CHANG, TY .
POLYMER, 1995, 36 (11) :2215-2218
[18]  
LIPATOV YS, 1974, ADSORPTION POLYM
[19]   PROBLEMS IN DETERMINING COMPOSITIONAL HETEROGENEITY OF COPOLYMERS BY SIZE-EXCLUSION CHROMATOGRAPHY AND UV-RI DETECTION SYSTEM [J].
MORI, S ;
SUZUKI, T .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1981, 4 (10) :1685-1696
[20]  
MORI S, 1989, SIZE EXCLUSION CHROM, P100