An enhanced electrical resistance technique for foam drainage measurement

被引:23
作者
Barigou, M [1 ]
Deshpande, NS [1 ]
Wiggers, FN [1 ]
机构
[1] Univ Birmingham, Sch Chem Engn, Birmingham B15 2TT, W Midlands, England
基金
英国工程与自然科学研究理事会;
关键词
foam; drainage; electrical resistance; gamma-ray absorption; liquid holdup;
D O I
10.1016/S0927-7757(00)00842-6
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The ability to characterise the drainage behaviour of foams is of direct value to the design of foaming systems and control of foam structures. Traditional electrical resistance methods for characterising foam drainage do not take into consideration the effects of foam inhomogeneity, and in particular the hitherto unnoticed substantial liquid layer established on the wall during drainage. An improved electrical resistance technique has been developed for accurate measurement of foam resistance which includes the liquid layer at the wall. The multi-channel set-up allows measurement of the temporal and vertical variations in the electrical resistance of a standing foam. The liquid holdup in the foam is inferred by calibration against a gamma-ray absorption technique. The capability of the technique is demonstrated through drainage tests performed on different foaming systems. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:237 / 246
页数:10
相关论文
共 21 条
  • [11] MAGNETIC-RESONANCE IMAGES OF COARSENING INSIDE A FOAM
    GONATAS, CP
    LEIGH, JS
    YODH, AG
    GLAZIER, JA
    PRAUSE, B
    [J]. PHYSICAL REVIEW LETTERS, 1995, 75 (03) : 573 - 576
  • [12] Hewitt G.F., 1978, MEASUREMENT 2 PHASE
  • [13] MEASUREMENT OF FOAM DENSITY PROFILES USING AC CAPACITANCE
    HUTZLER, S
    VERBIST, G
    WEAIRE, D
    VANDERSTEEN, JA
    [J]. EUROPHYSICS LETTERS, 1995, 31 (08): : 497 - 502
  • [14] INTERPRETATION OF THE MAGNETIC-RESONANCE-IMAGING SIGNAL FROM A FOAM
    MCCARTHY, MJ
    [J]. AICHE JOURNAL, 1990, 36 (02) : 287 - 290
  • [15] Mysels K. J., 1959, Soap films: Studies of their Thinning and a Bibliography
  • [16] X-RAY-SCATTERING BY BLACK FOAM FILMS - NEW DATA-ANALYSIS
    PLATIKANOV, D
    GRAF, HA
    WEISS, A
    CLEMENS, D
    [J]. COLLOID AND POLYMER SCIENCE, 1993, 271 (01) : 106 - 107
  • [17] 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING OF A LIQUID FOAM
    PRAUSE, BA
    GLAZIER, JA
    GRAVINA, SJ
    MONTEMAGNO, CD
    [J]. JOURNAL OF PHYSICS-CONDENSED MATTER, 1995, 7 (40) : L511 - L516
  • [18] A REVIEW OF FOAM DRAINAGE
    Weaire, D.
    Hutzler, S.
    Verbist, G.
    Peters, E.
    [J]. ADVANCES IN CHEMICAL PHYSICS <D>, 1997, 102 : 315 - 374
  • [19] WEAIRE D, 1995, J PHYS CONDENS MATT, V7, pF217
  • [20] Foam measurement by the microconductivity technique: An assessment of its sensitivity to interfacial and environmental factors
    Wilde, PJ