Evaluation of an ultrasonic nebulizer interface for capillary electrophoresis and inductively coupled plasma mass spectrometry

被引:66
作者
Lu, QH [1 ]
Barnes, RM [1 ]
机构
[1] UNIV MASSACHUSETTS,DEPT CHEM,AMHERST,MA 01003
关键词
D O I
10.1006/mchj.1996.0086
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An interface for capillary electrophoresis (CE) and inductively coupled plasma mass spectrometry (ICP-MS) is developed with a commercial ultrasonic nebulizer, The CE ground path was provided through a coaxial liquid electrolyte flow surrounding the CE capillary. To accommodate this dual capillary arrangement, the ultrasonic nebulizer spray chamber sample uptake tube inner diameter was enlarged, Metallothioneins were separated and detected to characterize the interface and to compare it with a concentric-glass nebulizer interface. Capillary electrophoresis resolution was unaffected by the ultrasonic nebulizer interface. Signal intensity was improved 3-6- to 8.4-fold compared to the concentric nebulizer arrangement, while signal-to-noise ratio improvement was only 1.3- to 2.8-fold. Concentration detection limits for Cd-114, Cd-111, Zn-64, and Zn-66 are 0.082, 0.039, 1.18, and 1.15 ppm in metallothionein, while the corresponding absolute detection limits are 2.5, 1.2, 37, and 36 fg, respectively. (C) 1996 Academic Press, Inc.
引用
收藏
页码:129 / 143
页数:15
相关论文
共 37 条
[1]  
Chen F.-T. A., 1992, Patent No. [US5120413A, 5120413]
[2]   RAPID PROTEIN-ANALYSIS BY CAPILLARY ELECTROPHORESIS [J].
CHEN, FTA .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :445-453
[3]  
CHEN FTA, 1992, Patent No. 5139630
[4]   RAPID SEPARATION OF DNA RESTRICTION FRAGMENTS USING CAPILLARY ELECTROPHORESIS [J].
COHEN, AS ;
NAJARIAN, D ;
SMITH, JA ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1988, 458 :323-333
[5]   ELECTROPHORESIS OF PROTEINS IN UNCOATED CAPILLARIES WITH AMINES AND AMINO-SUGARS AS ELECTROLYTE ADDITIVES [J].
CORRADINI, D ;
RHOMBERG, A ;
CORRADINI, C .
JOURNAL OF CHROMATOGRAPHY A, 1994, 661 (1-2) :305-313
[6]   PROTOCOL FOR RESOLVING PROTEIN MIXTURES IN CAPILLARY ZONE ELECTROPHORESIS [J].
GORDON, MJ ;
LEE, KJ ;
ARIAS, AA ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1991, 63 (01) :69-72
[7]   PROBING THE CHARACTERISTICS OF METAL-BINDING PROTEINS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - ATOMIC-ABSORPTION SPECTROSCOPY AND INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
HIGH, KA ;
BLAIS, JS ;
METHVEN, BAJ ;
MCLAREN, JW .
ANALYST, 1995, 120 (03) :629-634
[8]   CHROMATOGRAPHY COUPLED WITH INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY AND INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY - A REVIEW [J].
HILL, SJ ;
BLOXHAM, MJ ;
WORSFOLD, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (04) :499-515
[9]   CAPILLARY ELECTROPHORESIS FOR DIAGNOSIS AND STUDIES OF HUMAN-DISEASE, PARTICULARLY METABOLIC DISORDERS [J].
JELLUM, E ;
THORSRUD, AK ;
TIME, E .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :455-465
[10]   APPLICATION OF HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS TO THE ANALYSIS OF CONFORMATION AND INTERACTION OF METAL-BINDING PROTEINS [J].
KAJIWARA, H .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :345-356