Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications

被引:287
作者
Cannata, JM [1 ]
Ritter, TA
Chen, WH
Silverman, RH
Shung, KK
机构
[1] Univ So Calif, Dept Biomed Engn, NIH Resource Med Ultrasound Transducer Technol, Los Angeles, CA 90089 USA
[2] Cornell Univ, Weill Med Coll, Dept Ophthalmol, New York, NY 10021 USA
关键词
D O I
10.1109/TUFFC.2003.1251138
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper discusses the design, fabrication, and testing of sensitive broadband lithium niobate (LiNbO3) single-element ultrasonic transducers in the 2080 MHz frequency range. Transducers of varying dimensions were built for an f# range of 2.0-3.1. The desired focal depths were achieved by either casting an acoustic lens on the transducer face or press-focusing the piezoelectric into a spherical curvature. For designs that required electrical impedance matching, a low impedance transmission line coaxial cable was used. All transducers were tested in a pulse-echo arrangement, whereby the center frequency, bandwidth, insertion. loss, and focal depth were measured. Several transducers were fabricated with center frequencies in the 20-80 MHz range with the measured -6 dB bandwidths and two-way insertion loss values ranging from 57 to 74% and 9.6 to 21.3 dB, respectively. Both transducer focusing techniques proved successful in producing highly sensitive, high-frequency, single-element, ultrasonic-imaging transducers. In vivo and in vitro ultrasonic backscatter microscope (UBM) images of human eyes were obtained with the 50 MHz transducers. The high sensitivity of these devices could possibly allow for an increase in depth of penetration, higher image signal-to-noise ratio (SNR), and improved image contrast at high frequencies when compared to previously reported results.
引用
收藏
页码:1548 / 1557
页数:10
相关论文
共 26 条
[1]  
ALBRECHT AP, 1977, ELECT DESIGNERS HDB
[2]   DESIGN OF EFFICIENT BROAD-BAND PIEZOELECTRIC TRANSDUCERS [J].
DESILETS, CS ;
FRASER, JD ;
KINO, GS .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (03) :115-125
[3]   Advances in ultrasound biomicroscopy [J].
Foster, FS ;
Pavlin, CJ ;
Harasiewicz, KA ;
Christopher, DA ;
Turnbull, DH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (01) :1-27
[4]   PRINCIPLES AND APPLICATIONS OF ULTRASOUND BACKSCATTER MICROSCOPY [J].
FOSTER, FS ;
PAVLIN, CJ ;
LOCKWOOD, GR ;
RYAN, LK ;
HARASIEWICZ, KA ;
BERUBE, L ;
RAUTH, AM .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (05) :608-617
[5]   A new ultrasound instrument for in vivo microimaging of mice [J].
Foster, FS ;
Zhang, MY ;
Zhou, YQ ;
Liu, G ;
Mehi, J ;
Cherin, E ;
Harasiewicz, KA ;
Starkoski, BG ;
Zan, L ;
Knapik, DA ;
Adamson, SL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (09) :1165-1172
[6]  
HOROWITZ P, 1989, ART ELECT, P879
[7]  
KINO GS, 1987, ACOUSTIC WAVES DEVIC, P27
[8]   A 100-200 MHz ultrasound biomicroscope [J].
Knapik, DA ;
Starkoski, B ;
Pavlin, CJ ;
Foster, FS .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (06) :1540-1549
[9]   Plant and animal organs and functions - A student-centred approach [J].
Lock, R ;
Richards, B .
JOURNAL OF BIOLOGICAL EDUCATION, 1996, 30 (01) :15-16
[10]   THE DESIGN OF PROTECTION CIRCUITRY FOR HIGH-FREQUENCY ULTRASOUND IMAGING-SYSTEMS [J].
LOCKWOOD, GR ;
HUNT, JW ;
FOSTER, FS .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (01) :48-55