Simultaneous flow cytometric measurement of viability and lymphocyte subset proliferation

被引:22
作者
Schmid, I
Hausner, MA
Cole, SW
Uittenbogaart, CH
Giorgi, JV
Jamieson, BD
机构
[1] Univ Calif Los Angeles, Sch Med, Dept Hematol Oncol, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Sch Med, Dept Microbiol & Immunol, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Sch Med, Dept Pediat, Los Angeles, CA 90095 USA
关键词
flow cytometry; cell death; permeabilitation; dead cell exclusion; immunofluorescence; DNA content; proliferation; CD3/CD28; stimulation; 7-aminoactinomycin D; TO-PRO-3;
D O I
10.1016/S0022-1759(00)00323-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Combined analysis of DNA content and immunofluorescence on single cells by flow cytometry provides information on the proliferative response of cellular sub-populations in mixed cell preparations. However, the presence of considerable numbers of dead (nonviable) cells impairs accurate flow cytometric data analysis, mainly, because dead cells can bind antibodies non-specifically and show alterations in their DNA staining profiles. We developed a rapid method for identification of dead cells by fluorescence in cell preparations that are: stained simultaneously for two-color immunofluorescence and DNA content. Cells are stained with 7-aminoactinomycin D (7-AAD) for dead cell discrimination and with fluorescein-isothiocyanate (FITC) and phycoerythrin (PE)-labeled monoclonal antibodies (mAb) for cell surface immunofluorescence. Diffusion of 7-AAD from stained, dead cells into unstained, live cells after cell permeabilization is blocked by the addition of its non-fluorescent analogue actinomycin D (AD). DNA is stained with red-excitable TO-PRO-3 iodide (TP3) which has an emission spectrum that can be effectively separated from the emissions of FITC, PE, and 7-AAD. TP3 staining is performed in the presence of ribonuclease A (RNAse) in phosphate-citrate buffer containing saponin (PCBS) at low pH. FITC fluorescence is sensitive to acid pH: therefore, PCBS is replaced after DNA staining with 1X PBS at pH 7.2 containing saponin to permit accurate detection of FITC immunofluorescence on the flow cytometer. We apply this method to the analysis of differential proliferation of lymphocyte subsets in cultures of human peripheral blood mononuclear cells (PBMC) with low viability. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:175 / 186
页数:12
相关论文
共 39 条
[1]   FLOW CYTOMETRIC DETECTION OF A 2-STEP CELL-DEATH INDUCED BY HYPERTHERMIA [J].
BOHMER, RM .
CYTOMETRY, 1985, 6 (03) :215-218
[2]  
BOYUM A, 1968, SCAND J CLIN LAB INV, VS 21, P77
[3]  
Cole SW, 1998, J IMMUNOL, V161, P610
[4]  
DANGL JL, 1982, CYTOMETRY, V2, P395
[5]   FEATURES OF APOPTOTIC CELLS MEASURED BY FLOW-CYTOMETRY [J].
DARZYNKIEWICZ, Z ;
BRUNO, S ;
DELBINO, G ;
GORCZYCA, W ;
HOTZ, MA ;
LASSOTA, P ;
TRAGANOS, F .
CYTOMETRY, 1992, 13 (08) :795-808
[6]   VISIBLE DIODE-LASERS CAN BE USED FOR FLOW CYTOMETRIC IMMUNOFLUORESCENCE AND DNA ANALYSIS [J].
DOORNBOS, RMP ;
DEGROOTH, BG ;
KRAAN, YM ;
VANDERPOEL, CJ ;
GREVE, J .
CYTOMETRY, 1994, 15 (03) :267-271
[7]  
FETTERHOFF TJ, 1993, CYTOMETRY S6, V6, P27
[8]   ROLE OF THE CD28 RECEPTOR IN T-CELL ACTIVATION [J].
JUNE, CH ;
LEDBETTER, JA ;
LINSLEY, PS ;
THOMPSON, CB .
IMMUNOLOGY TODAY, 1990, 11 (06) :211-216
[9]  
Keeney M, 1998, CYTOMETRY, V34, P280, DOI 10.1002/(SICI)1097-0320(19981215)34:6<280::AID-CYTO6>3.0.CO
[10]  
2-H