Using a set of 55 Staphylococcus aureus challenge organisms, we evaluated six routine methods (broth microdilution, disk diffusion, oxacillin agar screen, MicroScan conventional panels, MicroScan rapid panels, and Vitek cards) currently used in many clinical laboratories and two new rapid methods, Velogene and the MRSA-Screen, that require less than a day to determine the susceptibility of S. aureus to oxacillin. The methods were evaluated by using the presence of the mecA gene, as detected by PCR, as the "gold standard." The strains included 19 mecA-positive heterogeneously resistant strains of expression class 1 or 2 (demonstrating oxacillin MICs of 4 to > 16 mug/ml) and 36 mecA-negative strains. The oxacillin MICs of the latter strains were 0.25 to 4 mug/ml when tested by broth microdilution with 2% NaCl-supplemented cation-adjusted Mueller-Hinton broth as specified by the NCCLS. However, when tested by agar dilution with 4% salt (the conditions used in the oxacillin agar screen method), the oxacillin MICs of 16 of the mecA-negative strains increased to 4 to 8 mug/ml. On initial testing, the percentages of correct results (% sensitivity/% specificity) were as follows: broth microdilution, 100/100; Velogene, 100/100; Vitek, 95/97; oxacillin agar screen, 90/92; disk diffusion, 100/89; MicroScan rapid panels, 90/86; MRSA-Screen, 90/100; and MicroScan conventional, 74/97. The MRSA-Screen sensitivity improved to 100% if agglutination reactions were read at 15 min. Repeat testing improved the performance of some but not all of the systems.
引用
收藏
页码:3785 / 3788
页数:4
相关论文
共 27 条
[1]   MULTIPLEX POLYMERASE CHAIN-REACTION FOR DETECTION OF GENES FOR STAPHYLOCOCCUS-AUREUS THERMONUCLEASE AND METHICILLIN RESISTANCE AND CORRELATION WITH OXACILLIN RESISTANCE [J].
BRAKSTAD, OG ;
MAELAND, JA ;
TVETEN, Y .
APMIS, 1993, 101 (09) :681-688
[2]   Evaluation of MRSA-screen, a simple anti-PBP 2a slide latex agglutination kit, for rapid detection of methicillin resistance in Staphylococcus aureus [J].
Cavassini, M ;
Wenger, A ;
Jaton, K ;
Blanc, DS ;
Bille, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (05) :1591-1594
[3]   The reliability of Microscan™ conventional and rapid panels to identify Staphylococcus aureus and detect methicillin resistance:: An evaluation using the tube coagulase test and mecA PCR [J].
Farrell, DJ .
PATHOLOGY, 1997, 29 (04) :406-410
[4]   Comparison of ATB Staph, Rapid ATB Staph, Vitek, and E-test methods for detection of oxacillin heteroresistance in staphylococci possessing mecA [J].
Frebourg, NB ;
Nouet, D ;
Lemée, L ;
Martin, E ;
Lemeland, JF .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (01) :52-57
[5]   COMPARISON OF CONVENTIONAL SUSCEPTIBILITY TESTS WITH DIRECT DETECTION OF PENICILLIN-BINDING PROTEIN-2A IN BORDERLINE OXACILLIN-RESISTANT STRAINS OF STAPHYLOCOCCUS-AUREUS [J].
GERBERDING, JL ;
MIICK, C ;
LIU, HH ;
CHAMBERS, HF .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1991, 35 (12) :2574-2579
[6]   2-PERCENT SODIUM-CHLORIDE IS REQUIRED FOR SUSCEPTIBILITY TESTING OF STAPHYLOCOCCI WITH OXACILLIN WHEN USING AGAR-BASED DILUTION METHODS [J].
HUANG, MB ;
GAY, TE ;
BAKER, CN ;
BANERJEE, SN ;
TENOVER, FC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (10) :2683-2688
[7]   Evaluation of a latex agglutination assay for rapid detection of oxacillin resistant Staphylococcus aureus [J].
Jafri, AK ;
Reisner, BS ;
Woods, GL .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2000, 36 (01) :57-59
[8]   Evaluation of vitek GPS-SA card for testing of oxacillin against borderline-susceptible staphylococci that lack mec [J].
Knapp, CC ;
Ludwig, MD ;
Washington, JA ;
Chambers, HF .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (07) :1603-1605
[9]   EVALUATION OF DIFFERENTIAL INOCULUM DISK DIFFUSION METHOD AND VITEK GPS-SA CARD FOR DETECTION OF OXACILLIN-RESISTANT STAPHYLOCOCCI [J].
KNAPP, CC ;
LUDWIG, MD ;
WASHINGTON, JA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (02) :433-436
[10]   ASSESSMENT OF OXACILLIN SALT AGAR FOR DETECTION OF MRSA IDENTIFIED BY PRESENCE OF THE MECA GENE [J].
KOBAYASHI, Y ;
KIZAKI, M ;
KAWAKAMI, Y ;
UCHIDA, H ;
IKEDA, Y .
JOURNAL OF HOSPITAL INFECTION, 1993, 23 (04) :279-285