Conducting electroactive polymer-based biosensors

被引:151
作者
Wallace, GG
Smyth, M
Zhao, H
机构
[1] Univ Wollongong, Intelligent Polymer Res Inst, Wollongong, NSW 2522, Australia
[2] Dublin City Univ, Sch Chem Sci, Dublin 9, Ireland
[3] Griffith Univ, Sch Appl Sci, Southport, Qld 4217, Australia
基金
澳大利亚研究理事会;
关键词
conducting polymers; biosensors; polymers;
D O I
10.1016/S0165-9936(98)00113-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Conductive electroactive polymers are materials discovered just on two decades ago. Originally heralded for their high conductivity/weight ratio, it is the unique chemical properties they possess that now arouse much attention. The ability to synthesise these materials under mild conditions enables a range of biological moieties (enzymes, antibodies and even whole living cells) to be incorporated into the polymer structure. The unique electronic properties then allow direct and interactive communication with the biochemistries incorporated to produce a range of analytical signals, This work reviews the options available for immobilisation of biocomponents and signal generation using conducting polymer-based biosensors, (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 61 条
[1]  
ABDOU MSA, 1997, HDB ORGANIC CONDUCTI, pCH5
[2]  
Adams R.N., 1969, Electrochemistry at Solid Electrodes
[3]   Electroimmobilisation of sulphite oxidase into a polypyrrole film and its utilisation for flow amperometric detection of sulphite [J].
Adeloju, SB ;
Barisci, JN ;
Wallace, GG .
ANALYTICA CHIMICA ACTA, 1996, 332 (2-3) :145-153
[4]   POLYPYRROLE-BASED POTENTIOMETRIC BIOSENSOR FOR UREA .2. ANALYTICAL OPTIMIZATION [J].
ADELOJU, SB ;
SHAW, SJ ;
WALLACE, GG .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :621-627
[5]   POLYPYRROLE-BASED POTENTIOMETRIC BIOSENSOR FOR UREA .1. INCORPORATION OF UREASE [J].
ADELOJU, SB ;
SHAW, SJ ;
WALLACE, GG .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :611-620
[6]   POLYPYRROLE-BASED AMPEROMETRIC BIOSENSOR FOR SULFITE DETERMINATION [J].
ADELOJU, SB ;
SHAW, SJ ;
WALLACE, GG .
ELECTROANALYSIS, 1994, 6 (10) :865-870
[7]   CHARACTERIZATION OF POLYPYRROLE FILMS ELECTRODEPOSITED BY WATER SOLUTIONS - EFFECT OF THE SUPPORTING ELECTROLYTE AND CYTOCHROME-C IMMOBILIZATION [J].
AGOSTIANO, A ;
CASELLI, M ;
DELLAMONICA, M ;
LAERA, S .
ELECTROCHIMICA ACTA, 1993, 38 (17) :2581-2588
[8]  
ATKINSON J, 1991, AH S SENS, P541
[9]   Studies of the preparation and analytical application of polypyrrole-coated microelectrodes for determination of aluminum [J].
Barisci, JN ;
Murray, P ;
Small, CJ ;
Wallace, GG .
ELECTROANALYSIS, 1996, 8 (04) :330-335
[10]   Electrochemical preparation of polypyrrole colloids using a flow cell [J].
Barisci, JN ;
Mansouri, J ;
Spinks, GM ;
Wallace, GG ;
Kim, CY ;
Kim, DY ;
Kim, JY .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1997, 126 (2-3) :129-135