Immobilization of DNAzyme catalytic beacons on PMMA for Pb2+ detection

被引:63
作者
Dalavoy, Tulika S. [1 ,2 ,3 ]
Wernette, Daryl P. [2 ,3 ]
Gong, Maojun [2 ,3 ]
Sweedler, Jonathan V. [2 ,3 ]
Lu, Yi [2 ,3 ]
Flachsbart, Bruce R. [4 ]
Shannon, Mark A. [4 ]
Bohn, Paul W. [5 ,6 ]
Cropek, Donald M. [1 ]
机构
[1] USA Corps Engineers, Construct Engn Res Lab, Champaign, IL 61822 USA
[2] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[3] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
[4] Univ Illinois, Dept Mech Sci & Engn, Urbana, IL 61801 USA
[5] Univ Notre Dame, Dept Chem & Biomol Engn, Notre Dame, IN 46556 USA
[6] Univ Notre Dame, Dept Chem & Biochem, Notre Dame, IN 46556 USA
关键词
D O I
10.1039/b718624j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Due to the numerous toxicological effects of lead, its presence in the environment needs to be effectively monitored. Incorporating a biosensing element within a microfluidic platform enables rapid and reliable determinations of lead at trace levels. A microchip-based lead sensor is described here that employs a lead-specific DNAzyme (also called catalytic DNA or deoxyribozyme) as a recognition element that cleaves its complementary substrate DNA strand only in the presence of cationic lead (Pb2+). Fluorescent tags on the DNAzyme translate the cleavage events to measurable, optical signals proportional to Pb2+ concentration. The DNAzyme responds sensitively and selectively to Pb2+, and immobilizing DNAzyme in the sensor permits both sensor regeneration and localization of the detection zone. Here, the DNAzyme has been immobilized on a PMMA surface using the highly specific biotin-streptavidin interaction. The strategy includes using streptavidin physisorbed on a PMMA surface to immobilize DNAzyme both on planar PMMA and on the walls of a PMMA microfluidic device. The immobilized DNAzyme retains its Pb2+ detection activity in the microfluidic device and can be regenerated and reused. The DNAzyme shows no response to other common metal cations and the presence of these contaminants does not interfere with the lead-induced fluorescence signal. While prior work has shown lead-specific catalytic DNA can be used in its solubilized form and while attached to gold substrates to quantitate Pb2+ in solution, this is the first use of the DNAzyme immobilized within a microfluidic platform for real time Pb2+ detection.
引用
收藏
页码:786 / 793
页数:8
相关论文
共 25 条
[1]   A lead-dependent DNAzyme with a two-step mechanism [J].
Brown, AK ;
Li, J ;
Pavot, CMB ;
Lu, Y .
BIOCHEMISTRY, 2003, 42 (23) :7152-7161
[2]   Miniaturized lead sensor based on lead-specific DNAzyme in a manocapillary interconnected microfluidic device [J].
Chang, IH ;
Tulock, JJ ;
Liu, JW ;
Kim, WS ;
Cannon, DM ;
Lu, Y ;
Bohn, PW ;
Sweedler, JV ;
Cropek, DM .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (10) :3756-3761
[3]   Direct-write laser micromachining and universal surface modification of PMMA for device development [J].
Cheng, JY ;
Wei, CW ;
Hsu, KH ;
Young, TH .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (01) :186-196
[4]   Dinucleotide junction cleavage versatility of 8-17 deoxyribozyme [J].
Cruz, RPG ;
Withers, JB ;
Li, YF .
CHEMISTRY & BIOLOGY, 2004, 11 (01) :57-67
[5]   A study on photolinkers used for biomolecule attachment to polymer surfaces [J].
Dankbar, Daniela M. ;
Gauglitz, Guenter .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (7-8) :1967-1974
[6]   Profiling pH gradients across nanocapillary array membranes connecting microfluidic channels [J].
Fa, K ;
Tulock, JJ ;
Sweedler, JV ;
Bohn, PW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (40) :13928-13933
[7]   The Ca2+ ion as a cofactor for a novel RNA-cleaving deoxyribozyme [J].
Faulhammer, D ;
Famulok, M .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1996, 35 (23-24) :2837-2841
[8]   Functionalization of poly(methyl methacrylate) (PMMA) as a substrate for DNA microarrays [J].
Fixe, F ;
Dufva, M ;
Telleman, P ;
Christensen, CBV .
NUCLEIC ACIDS RESEARCH, 2004, 32 (01) :e9
[9]   Design and fabrication of a multilayered polymer microfluidic chip with nanofluidic interconnects via adhesive contact printing [J].
Flachsbart, BR ;
Wong, K ;
Iannacone, JM ;
Abante, EN ;
Vlach, RL ;
Rauchfuss, PA ;
Bohn, PW ;
Sweedler, JV ;
Shannon, MA .
LAB ON A CHIP, 2006, 6 (05) :667-674
[10]   Nanofluidic injection and heterogeneous kinetics of organomercaptan surface displacement reactions on colloidal gold in a microfluidic stream [J].
Kirk, JS ;
Sweedler, JV ;
Bohn, PW .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2335-2341