The unispacer knee implant - Early clinical results

被引:27
作者
Bailie, A. G. [1 ]
Lewis, P. L. [1 ]
Brumby, S. A. [1 ]
Roy, S. [1 ,2 ]
Paterson, R. S. [1 ]
Campbell, D. G. [1 ]
机构
[1] Wakefield Orthopaed Clin, Adelaide, SA, Australia
[2] Royal Glamorgan Hosp, Llantrisant CF72 8XR, Wales
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2008年 / 90B卷 / 04期
关键词
D O I
10.1302/0301-620X.90B4.20319
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Unispacer knee system is a cobalt-chrome self-centring tibial hemiarthroplasty device for use in the treatment of isolated medial compartment osteoarthritis of the knee. The indications for use are similar to those for high tibial osteotomy, but insertion does not require bone cuts or component fixation, and does not compromise future knee replacement surgery. A prospective study of a consecutive series of 18 patients treated with the Unispacer between June 2003 and August 2004 was carried out to determine the early clinical results of this device. The mean age of the patients was 49 years ( 40 to 57). A total of eight patients ( 44%) required revision within two years. In two patients revision to a larger spacer was required, and in six conversion to either a unicompartmental or total knee replacement was needed. At the most recent review 12 patients ( 66.7%) had a Unispacer remaining in situ. The mean modified visual analogue score for these patients at a mean follow-up of 19 months ( 12 to 26) was 3.0 ( 0 to 11.5). The mean pain level was 30% that of the mean pre-operative level of 10. The early clinical results using this device have been disappointing. This study demonstrates that use of the Unispacer in isolated medial compartment osteoarthritis is associated with a high rate of revision surgery and provides unpredictable relief of pain.
引用
收藏
页码:446 / 450
页数:5
相关论文
共 22 条
[1]
High tibial osteotomy for the treatment of unicompartmental arthritis of the knee [J].
Amendola, A ;
Panarella, L .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2005, 36 (04) :497-+
[2]
Comparison of wear in a total knee replacement under different kinematic conditions [J].
Barnett, PI ;
Fisher, J ;
Auger, DD ;
Stone, MH ;
Ingham, E .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (10-12) :1039-1042
[3]
High tibial osteotomy for medial compartment osteoarthritis [J].
Dowd, GSE ;
Somayaji, HS ;
Uthukuri, M .
KNEE, 2006, 13 (02) :87-92
[4]
Duffy GP, 1998, CLIN ORTHOP RELAT R, P22
[5]
THE USE OF THE MCKEEVER METALLIC HEMIARTHROPLASTY FOR UNICOMPARTMENTAL ARTHRITIS [J].
EMERSON, RH ;
POTTER, T .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (02) :208-212
[6]
GALWAY HR, 1980, CLIN ORTHOP RELAT R, P45
[7]
The UniSpacer: A treatment alternative for the middle-aged patient [J].
Hallock, RH .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2005, 36 (04) :505-+
[8]
Unicompartmental tibial hemiarthroplasty -: Early results of the UniSpacer™ knee [J].
Hallock, RH ;
Fell, BM .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) :154-163
[9]
Jones DL, 2004, J RHEUMATOL, V31, P1384
[10]
McKeever D.C., 1960, CLIN ORTHOP RELAT R, V18, P86