Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: Results in 122 patients

被引:240
作者
Klein, JS [1 ]
Salomon, G [1 ]
Stewart, EA [1 ]
机构
[1] ST JOSEPHS HOSP,DEPT RADIOL,PHOENIX,AZ
关键词
lung; biopsy; granuloma; lung neoplasms; diagnosis;
D O I
10.1148/radiology.198.3.8628859
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the utility of coaxial transthoracic needle biopsy (TNB) with use of a 20-gauge automated cutting biopsy needle in the diagnosis of thoracic lesions. MATERIALS AND METHODS: A retrospective review was performed in 122 patients. Computed tomography was used to guide coaxial TNB, which was performed with aspirating (n = 87) and automated cutting (n = 99) needles. The sensitivities for malignant and benign lesions were determined, with a comparison of the relative yields from the two techniques. RESULTS: The overall diagnostic yield for coaxial TNB was 88%. For malignancy the sensitivity was 95%, whereas a specific benign diagnosis was obtained in 91%. Although no difference was found for fine-needle aspiration versus core biopsy of malignant lesions (92% vs 86%), a statistically significant difference was found for benign lesions (44% vs 100%, P <.05). Pneumothorax occurred in 54%. CONCLUSION Coaxial TNB performed with an automated cutting needle helps provide a diagnosis in the majority of patients with focal chest disease and is particularly useful in the diagnosis of benign lesions.
引用
收藏
页码:715 / 720
页数:6
相关论文
共 17 条
  • [1] VALUE OF HAVING A CYTOPATHOLOGIST PRESENT DURING PERCUTANEOUS FINE-NEEDLE ASPIRATION BIOPSY OF LUNG - REPORT OF 55 CANCER-PATIENTS AND METAANALYSIS OF THE LITERATURE
    AUSTIN, JHM
    COHEN, MB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (01) : 175 - 177
  • [2] LOW-RISK LARGE-NEEDLE BIOPSY OF CHEST LESIONS
    CLORE, F
    VIRAPONGSE, C
    SATERFIEL, J
    [J]. CHEST, 1989, 96 (03) : 538 - 541
  • [3] FRASER RS, 1991, ARCH PATHOL LAB MED, V115, P751
  • [4] GOBIEN RP, 1985, RADIOLOGY, V145, P603
  • [5] CT-GUIDED CUTTING-NEEDLE BIOPSIES OF SELECTED CHEST LESIONS
    GORALNIK, CH
    OCONNELL, DM
    ELYOUSEF, SJ
    HAAGA, JR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (05) : 903 - 907
  • [6] CT-GUIDED AUTOMATED NEEDLE-BIOPSY OF THE CHEST
    HARAMATI, LB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (01) : 53 - 55
  • [7] TUMORS IN THE MEDIASTINUM - US-GUIDED HISTOLOGIC CORE-NEEDLE BIOPSY
    HEILO, A
    [J]. RADIOLOGY, 1993, 189 (01) : 143 - 146
  • [8] TRANS-THORACIC NEEDLE ASPIRATION BIOPSY OF BENIGN AND MALIGNANT LUNG LESIONS
    KHOURI, NF
    STITIK, FP
    EROZAN, YS
    GUPTA, PK
    KIM, WS
    SCOTT, WW
    HAMPER, UM
    MANN, RB
    EGGLESTON, JC
    BAKER, RR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (02) : 281 - 288
  • [9] EVALUATION AND COMPARISON OF AUTOMATED BIOPSY DEVICES - WORK IN PROGRESS
    MLADINICH, CRJ
    ACKERMAN, N
    BERRY, CR
    BUERGELT, CD
    LONGMATE, J
    [J]. RADIOLOGY, 1992, 184 (03) : 845 - 847
  • [10] POSITIONAL PRECAUTIONS IN NEEDLE ASPIRATION LUNG-BIOPSY
    MOORE, EH
    SHEPARD, JAO
    MCLOUD, TC
    TEMPLETON, PA
    KOSIUK, JP
    [J]. RADIOLOGY, 1990, 175 (03) : 733 - 735