A highly sensitive and selective assay for cysteine using the chemiluminescence reaction of luminol and hydrogen peroxide

被引:30
作者
Li, YX [1 ]
Zhu, CQ [1 ]
Wang, L [1 ]
机构
[1] Anhui Normal Univ, Coll Chem & Mat Sci, Wuhu 241000, Peoples R China
关键词
chemiluminescence; cysteine; luminol; flow-injection;
D O I
10.1007/s00604-005-0317-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A very simple, highly sensitive and selective chemiluminescence ( CL) method was established for the determination of cysteine. This method is based on the fact that the CL reaction of luminol and hydrogen peroxide can be greatly enhanced by cysteine. The CL intensities at maximum light emission were linearly correlated with the concentration of cysteine over the range of 2.0 x 10(-8) -6.0 x 10(-6) mol L-1 with a detection limit of 7.5 x 10(-9) mol L-1. The relative standard deviation was 1.7% for the determination of 1.0 x 10(-7) mol L-1 cysteine (n = 9). The feasibility of utilizing the proposed method for the determination of total concentration of cysteine in human serum was examined.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 23 条
[1]  
ALIQYRESHI G, 1984, J CHROMATOGR, V297, P91
[2]  
ALIQYRESHI G, 1989, J CHROMAOTGR, V491, P281
[3]   CHEMILUMINESCENCE DETERMINATION OF BUPRENORPHINE HYDROCHLORIDE BY FLOW-INJECTION ANALYSIS [J].
ALWARTHAN, AA ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1986, 185 :329-333
[4]   Specific determination of cysteine and penicillamine through cyclization to 2-thioxothiazolidine-4-carboxylic acids [J].
Amarnath, V ;
Amarnath, K .
TALANTA, 2002, 56 (04) :745-751
[5]   Simultaneous determination of cysteine, cystine and 18 other amino acids in various matrices by high-performance liquid chromatography [J].
Campanella, L ;
Crescentini, G ;
Avino, P .
JOURNAL OF CHROMATOGRAPHY A, 1999, 833 (02) :137-145
[6]   Determination of cysteine in human plasma by high-performance liquid chromatography and ultraviolet detection after pre-column derivatization with 2-chloro-1-methylpyridinium iodide [J].
Chwatko, G ;
Bald, E .
TALANTA, 2000, 52 (03) :509-515
[7]   Role of cysteine and glutathione in signal transduction, immunopathology and cachexia [J].
Dröge, W ;
Hack, V ;
Breitkreutz, R ;
Holm, E ;
Shubinsky, G ;
Schmid, E ;
Galter, D .
BIOFACTORS, 1998, 8 (1-2) :97-102
[8]   APPLICATION OF AMINO-ACID-ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHENYL ISOTHIOCYANATE DERIVATIZATION TO THE RAPID-DETERMINATION OF FREE AMINO-ACIDS IN BIOLOGICAL SAMPLES [J].
FIERABRACCI, V ;
MASIELLO, P ;
NOVELLI, M ;
BERGAMINI, E .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (02) :285-291
[9]  
JACOBSEN DW, 1994, CLIN CHEM, V40, P873
[10]   Resolution of amino thiols in time-resolved luminol chemiluminescence catalyzed by peroxidases [J].
Kamidate, T ;
Tani, T ;
Watanabe, H .
ANALYTICAL SCIENCES, 1998, 14 (04) :725-729