Palmar plating system for Colles′ fractures -: A preliminary report

被引:71
作者
Kamano, M
Koshimune, M
Toyama, M
Kazuki, K
机构
[1] Saiseikai Nakatsu Hosp, Dept Orthopaed Surg, Kita Ku, Osaka 5300012, Japan
[2] Baba Mem Hosp, Dept Orthopaed Surg, Osaka, Japan
[3] Osaka City Univ, Sch Med, Dept Orthopaed Surg, Osaka 545, Japan
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2005年 / 30A卷 / 04期
关键词
Colles' fracture; palmar plating; subchondral screw fixation;
D O I
10.1016/j.jhsa.2005.02.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To present our results of the palmar plating system that we developed for the treatment of Colles' fractures. Methods: By using the palmar plating system that we developed a consecutive series of 40 acute Colles' fractures were treated surgically. There were 12 men and 28 women with a mean age of 57 years at the time of the injury (range, 25-90 y). All patients had internal fixation using the trans-flexor carpi radialis tendon approach. The system has 3 main features. First, the plate is small in size, being 1.1 mm in thickness and 47 mm in length. Only a 3- to 4-cm skin incision is required for application of the plate. Second, the screw is cannulated and cancellous in type, with a low-profile head. Subchondral screw fixation is achieved both easily and safely by using a guidewire. Third, the plate has a window through which injectable bone cement can be placed. Results: Union was achieved in all patients. The palmar tilt, radial inclination, radial length, and ulnar variance were maintained after surgery. According to the Gartland and Werley rating scale that was modified by Sarmiento there were 12 excellent and 28 good results. There were no extensor tendon injuries that could occur when the dorsal approach was used. Conclusions: This palmar plating system can make fixation of the distal radius easy, safe, and effective in the treatment of unstable Colles' fractures.
引用
收藏
页码:750 / 755
页数:6
相关论文
共 15 条
[1]
Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures [J].
Carter, PR ;
Frederick, HA ;
Laseter, GF .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (02) :300-307
[2]
Constantine KJ, 2002, ORTHOPEDICS, V25, P125
[3]
GARTLAND JJ, 1951, J BONE JOINT SURG AM, V33, P805
[4]
GEORGOULIS A, 1992, Aktuelle Traumatologie, V22, P9
[5]
Kamano M, 2002, CLIN ORTHOP RELAT R, P403
[6]
Palmar plating with calcium phosphate bone cement for unstable Colles' fractures [J].
Kamano, M ;
Honda, Y ;
Kazuki, K ;
Yasuda, M .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) :285-290
[7]
Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius:: A brief report [J].
Kambouroglou, GK ;
Axelrod, TS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (04) :737-741
[8]
Complications in internal fixation of the distal radius [J].
Lucas, GL ;
Fejfar, ST .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (06) :1117-1117
[9]
Orbay J L, 2000, Hand Surg, V5, P103, DOI 10.1142/S0218810400000223
[10]
Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report [J].
Orbay, JL ;
Fernandez, DL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2002, 27A (02) :205-215