Poor agreement among prothrombin time international normalized ratio methods: Comparison of seven commercial reagents

被引:56
作者
Horsti, J [1 ]
Uppa, H
Vilpo, JA
机构
[1] Tampere Univ Hosp, Dept Clin Chem, Lab Ctr, FIN-33521 Tampere, Finland
[2] Univ Tampere, FIN-33101 Tampere, Finland
关键词
D O I
10.1373/clinchem.2004.043836
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Prothrombin time (PT) has long been the most popular test for monitoring oral anticoagulation therapy. The International Normalized Ratio (INR) was introduced to overcome the problem of marked variation in PT results among laboratories and the various recommendations for patient care. According to this principle, all reagents should be calibrated to give identical results and the same patient care globally. This is necessary for monitoring of single patients and for application of the results of anticoagulation trials and guidelines to clinical practice. Methods: We took blood samples from 150 patients for whom oral anticoagulation had been prescribed. Plasmas were separated and PTs determined by use of seven commercial reagents and four calibrator sets. The differences in results were assessed by plotting, for each possible pair of methods, the differences in INR values for each sample against the mean INR value (Bland-Altman difference plots). Results: Mean results differed significantly (P <0.001) for 17 of 21 possible paired comparisons of methods. Only two pairs of methods produced very similar results when assessed for problems of substantial differences in INR values; a significant, systematic increase in the difference with INR; and a significant systematic increase in the variation in difference with increasing INR values. Conclusions: The agreement among several (and perhaps most) commercial INR methods is poor. The failure of current calibration strategies may severely compromise both the monitoring of individual patients and the application of oral anticoagulation guidelines and trial results to clinical practice. (C) 2005 American Association for Clinical Chemistry.
引用
收藏
页码:553 / 560
页数:8
相关论文
共 30 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   THE RELIABILITY OF MANUFACTURER-DETERMINED, INSTRUMENT-SPECIFIC INTERNATIONAL SENSITIVITY INDEX VALUES FOR CALCULATING THE INTERNATIONAL NORMALIZED RATIO [J].
CUNNINGHAM, MT ;
JOHNSON, GF ;
PENNELL, BJ ;
OLSON, JD .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1994, 102 (01) :128-133
[3]  
DEITCHER SR, 2003, WINTROBES CLIN HEMAT, P1713
[4]   Perioperative management of patients receiving oral anticoagulants - A systematic review [J].
Dunn, AS ;
Turpie, AGG .
ARCHIVES OF INTERNAL MEDICINE, 2003, 163 (08) :901-908
[5]   Management and dosing of warfarin therapy [J].
Gage, BF ;
Fihn, SD ;
White, RH .
AMERICAN JOURNAL OF MEDICINE, 2000, 109 (06) :481-488
[6]   NATURE OF PROTHROMBIN BIOSYNTHESIS - PREPROTHROMBINAEMIA IN VITAMIN K-DEFICIENCY [J].
HEMKER, HC ;
HENSEN, A ;
LOELIGER, EA ;
VELTKAMP, JJ .
NATURE, 1963, 200 (490) :589-&
[7]   OPTIMAL INTENSITY AND MONITORING WARFARIN [J].
HIRSH, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (06) :B39-B42
[8]   Mechanism of action, clinical effectiveness, and optimal therapeutic range [J].
Hirsh, J ;
Dalen, JE ;
Anderson, DR ;
Poller, L ;
Bussey, H ;
Ansell, J ;
Deykin, D ;
Brandt, JT .
CHEST, 1998, 114 (05) :445S-469S
[9]   The Quick and Owren prothrombin time methods for oral anticoagulant therapy do not agree well using the International Normalized Ratio (INR) units [J].
Horsti, J .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2003, 63 (06) :455-456
[10]   Has the Quick or the Owren prothrombin time method the advantage in harmonization for the International Normalized Ratio system? [J].
Horsti, J .
BLOOD COAGULATION & FIBRINOLYSIS, 2002, 13 (07) :641-646