Safety of MR liver specific contrast media

被引:33
作者
Bellin, MF
Webb, JAW
Van der Molen, AJ
Thomsen, HS
Morcos, SK
机构
[1] Univ Copenhagen, Herlev Hosp, Dept Diagnost Radiol, DK-2730 Herlev, Denmark
[2] Univ Paris 11, Hop Paul Brousse, AP HP, Serv Radiol, F-94804 Villejuif, France
[3] St Bartholomews Hosp, Dept Diagnost Imaging, London EC1A 7BE, England
[4] Leiden Univ, Med Ctr, Dept Radiol C2S, NL-2300 RC Leiden, Netherlands
[5] Sheffield Teaching Hosp NHS Trust, No Gen Hosp, Dept Diagnost Imaging, Sheffield S5 7AU, S Yorkshire, England
关键词
contrast media; MR scanning; liver; iron oxide; manganese; gadolinium;
D O I
10.1007/s00330-004-2612-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Over the past few years a number of magnetic resonance (MR) liver specific contrast agents have been introduced. In this report the safety issues of these agents are addressed. A literature search was carried out. Based on the available information, simple guidelines on the safety issue of liver specific contrast agents have been produced by the Contrast Media Safety Committee of the European Society of Urogenital Radiology. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela. Liver specific contrast agents appear in general to be safe and well tolerated. However, the incidence of adverse reactions with iron oxides and the intravenous manganese based agent seems to be slightly higher than with gadolinium based agents. However, no safety information from comparative clinical trials has been published. Guidelines on the safety aspects are presented.
引用
收藏
页码:1607 / 1614
页数:8
相关论文
共 51 条
[1]   MN-DPDP - ENHANCED MR-IMAGING OF MALIGNANT LIVER-LESIONS - EFFICACY AND SAFETY IN 20 PATIENTS [J].
AICHER, KP ;
LANIADO, M ;
KOPP, AF ;
GRONEWALLER, E ;
DUDA, SH ;
CLAUSSEN, CD .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05) :731-737
[2]   LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING [J].
BELLIN, MF ;
ZAIM, S ;
AUBERTON, E ;
SARFATI, G ;
DURON, JJ ;
KHAYAT, D ;
GRELLET, J .
RADIOLOGY, 1994, 193 (03) :657-663
[3]   Currently used non-specific extracellular MR contrast media [J].
Bellin, MF ;
Vasile, M ;
Morel-Precetti, S .
EUROPEAN RADIOLOGY, 2003, 13 (12) :2688-2698
[4]   Hepatic MR imaging with ferumoxides: Multicenter study of safety and effectiveness of direct injection protocol [J].
Bluemke, DA ;
Weber, TM ;
Rubin, D ;
de Lange, EE ;
Semelka, R ;
Redvanly, RD ;
Chezmar, J ;
Outwater, E ;
Carlos, R ;
Saini, S ;
Holland, GA ;
Mammone, JF ;
Brown, JJ ;
Milestone, B ;
Javitt, MC ;
Jacobs, P .
RADIOLOGY, 2003, 228 (02) :457-464
[5]  
Blume J, 1994, Acad Radiol, V1, P253, DOI 10.1016/S1076-6332(05)80725-1
[6]   Gadolinium-ethoxybenzyl-DTPA as a hepatobiliary contrast agent for use in MR cholangiography: Results of an in vivo phase-I clinical evaluation [J].
Bollow, M ;
Taupitz, M ;
Hamm, B ;
Staks, T ;
Wolf, KJ ;
Weinmann, HJ .
EUROPEAN RADIOLOGY, 1997, 7 (01) :126-132
[7]  
Breuer J, 2003, EUR RADIOL, V13, pS109
[8]   Focal malignant hepatic lesions: MR imaging enhanced with gadolinium benzyloxypropionictetra-acetate (BOPTA) - Preliminary results of phase II clinical application [J].
Caudana, R ;
Morana, G ;
Pirovano, GP ;
Nicoli, N ;
Portuese, A ;
Spinazzi, A ;
DiRito, R ;
Pistolesi, GF .
RADIOLOGY, 1996, 199 (02) :513-520
[9]   Gadolinium chelates with weak binding to serum proteins - A new class of high-efficiency, general purpose contrast agents for magnetic resonance imaging [J].
Cavagna, FM ;
Maggioni, F ;
Castelli, PM ;
Dapra, M ;
Imperatori, LG ;
Lorusso, V ;
Jenkins, BG .
INVESTIGATIVE RADIOLOGY, 1997, 32 (12) :780-796
[10]   PRECLINICAL EVALUATION OF MNDPDP - NEW PARAMAGNETIC HEPATOBILIARY CONTRAST AGENT FOR MR IMAGING [J].
ELIZONDO, G ;
FRETZ, CJ ;
STARK, DD ;
ROCKLAGE, SM ;
QUAY, SC ;
WORAH, D ;
TSANG, YM ;
CHEN, MCM ;
FERRUCCI, JT .
RADIOLOGY, 1991, 178 (01) :73-78